Kinematic viscosities of some common liquids:

Liquids - Kinematic Viscosities
LiquidTemperatureKinematic Viscosity
(oF)(oC)centiStokes (cSt)Seconds Saybolt Universal (SSU)
Acetaldehyde CH3CHO 61
68
16.1
20
0.305
0.295
36
Acetic acid - vinegar - 10% CH3COOH 59 15 1.35 31.7
Acetic acid - 50% 59 15 2.27 33
Acetic acid - 80% 59 15 2.85 35
Acetic acid - concentrated glacial 59 15 1.34 31.7
Acetic acid anhydride (CH3COO)2O 59 15 0.88
Acetone CH3COCH3 68 20 0.41
Alcohol - allyl 68
104
20
40
1.60
0.90 cp
31.8
Alcohol - butyl-n 68 20 3.64 38
Alcohol - ethyl (grain) C2H5OH 68
100
20
37.8
1.52
1.2
31.7
31.5
Alcohol - methyl (wood) CH3OH 59
32
15
0
0.74
1.04
Alcohol - propyl 68
122
20
50
2.8
1.4
35
31.7
Aluminum sulfate - 36% solution 68 20 1.41 31.7
Ammonia 0 -17.8 0.30
Aniline 68
50
20
10
4.37
6.4
40
46.4
Asphalt RC-0, MC-0, SC-0 77
100
25
37.8
159-324
60-108
737-1.5M
280-500
Automatic crankcase oil SAE 10W 0 -17.8 1295-max 6M-max
Automatic crankcase oil SAE 10W 0 -17.8 1295-2590 6M-12M
Automatic crankcase oil SAE 20W 0 -17.8 2590-10350 12M-48M
Automatic crankcase oil SAE 20 210 98.9 5.7-9.6 45-58
Automatic crankcase oil SAE 30 210 98.9 9.6-12.9 58-70
Automatic crankcase oil SAE 40 210 98.9 12.9-16.8 70-85
Automatic crankcase oil SAE 50 210 98.9 16.8-22.7 85-110
Automotive gear oil SAE 75W 210 98.9 4.2 min 40 min
Automotive gear oil SAE 80W 210 98.9 7.0 min 49 min
Automotive gear oil SAE 85W 210 98.9 11.0 min 63 min
Automotive gear oil SAE 90W 210 98.9 14-25 74-120
Automotive gear oil SAE 140 210 98.9 25-43 120-200
Automotive gear oil SAE150 210 98.9 43 - min 200 min
Beer 68 20 1.8 32
Benzene (Benzol) C6H6 32
68
0
20
1.0
0.74
31
Bone oil 130
212
54.4
100
47.5
11.6
220
65
Bromine 68 20 0.34
Butane-n -50
30
-1.1 0.52
0.35
Butyric acid n 68
32
20
0
1.61
2.3 cp
31.6
Calcium chloride 5% 65 18.3 1.156
Calcium chloride 25% 60 15.6 4.0 39
Carbolic acid (phenol) 65
194
18.3
90
11.83
1.26 cp
65
Carbon tetrachloride CCl4 68
100
20
37.8
0.612
0.53
Carbon disulfide CS2 32
68
0
20
0.33
0.298
Castor oil 100
130
37.8
54.4
259-325
98-130
1200-1500
450-600
China wood oil 69
100
20.6
37.8
308.5
125.5
1425
580
Chloroform 68
140
20
60
0.38
0.35
Coconut oil 100
130
37.8
54.4
29.8-31.6
14.7-15.7
140-148
76-80
Cod oil (fish oil) 100
130
37.8
54.4
32.1
19.4
150
95
Corn oil 130
212
54.4
100
28.7
8.6
135
54
Corn starch solution, 22 Baumé 70
100
21.1
37.8
32.1
27.5
150
130
Corn starch solution, 24 Baumé 70
100
21.1
37.8
129.8
95.2
600
440
Corn starch solution, 25 Baumé 70
100
21.1
37.8
303
173.2
1400
800
Cotton seed oil 100
130
37.8
54.4
37.9
20.6
176
100
Crude oil 48o API 60
130
15.6
54.4
3.8
1.6
39
31.8
Crude oil 40o API 60
130
15.6
54.4
9.7
3.5
55.7
38
Crude oil 35.6o API 60
130
15.6
54.4
17.8
4.9
88.4
42.3
Crude oil 32.6o API 60
130
15.6
54.4
23.2
7.1
110
46.8
Decane-n 0
100
17.8
37.8
2.36
1.001
34
31
Diethyl glycol 70 21.1 32 149.7
Diethyl ether 68 20 0.32
Diesel fuel 2D 100
130
37.8
54.4
2-6
1.-3.97
32.6-45.5
-39
Diesel fuel 3D 100
130
37.8
54.4
6-11.75
3.97-6.78
45.5-65
39-48
Diesel fuel 4D 100
130
37.8
54.4
29.8 max
13.1 max
140 max
70 max
Diesel fuel 5D 122
160
50
71.1
86.6 max
35.2 max
400 max
165 max
Ethyl acetate CH3COOC2H3 59
68
15
20
0.4
0.49
Ethyl bromide C2H5Br 68 20 0.27
Ethylene bromide 68 20 0.787
Ethylene chloride 68 20 0.668
Ethylene glycol 70 21.1 17.8 88.4
Formic acid 10% 68 20 1.04 31
Formic acid 50% 68 20 1.2 31.5
Formic acid 80% 68 20 1.4 31.7
Formic acid concentrated 68
77
20
25
1.48
1.57cp
31.7
Trichlorofluoromethane, R-11 70 21.1 0.21
Dichlorodifluoromethane, R-12 70 21.1 0.27
FDichloro-fluoromethane, R-21 70 21.1 1.45
Furfurol 68
77
20
25
1.45
1.49cp
31.7
Fuel oil 1 70
100
21.1
37.8
2.39-4.28
-2.69
34-40
32-35
Fuel oil 2 70
100
21.1
37.8
3.0-7.4
2.11-4.28
36-50
33-40
Fuel oil 3 70
100
21.1
37.8
2.69-5.84
2.06-3.97
35-45
32.8-39
Fuel oil 5A 70
100
21.1
37.8
7.4-26.4
4.91-13.7
50-125
42-72
Fuel oil 5B 70
100
21.1
37.8
26.4-
13.6-67.1
125-
72-310
Fuel oil 6 122
160
50
71.1
97.4-660
37.5-172
450-3M
175-780
Gas oils 70
100
21.1
37.8
13.9
7.4
73
50
Gasoline a 60
100
15.6
37.8
0.88
0.71
Gasoline b 60
100
15.6
37.8
0.64
Gasoline c 60
100
15.6
37.8
0.46
0.40
Glycerine 100% 68.6
100
20.3
37.8
648
176
2950
813
Glycerine 50% water 68
140
20
60
5.29
1.85 cp
43
Glycol 68 52
Glucose 100
150
37.8
65.6
7.7M-22M
880-2420
35M-100M
4M-11M
Heptanes-n 0
100
-17.8
37.8
0.928
0.511
Hexane-n 0
100
-17.8
37.8
0.683
0.401
Honey 100 37.8 73.6 349
Hydrochloric acid 68 1.9
Ink, printers 100
130
37.8
54.4
550-2200
238-660
2500-10M
1100-3M
Insulating oil 70
100
21.1
37.8
24.1 max
11.75 max
115 max
65 max
Kerosene 68 20 2.71 35
Jet Fuel -30. -34.4 7.9 52
Lard 100
130
37.8
54.4
62.1
34.3
287
160
Lard oil 100
130
37.8
54.4
41-47.5
23.4-27.1
190-220
112-128
Linseed oil 100
130
37.8
54.4
30.5
18.94
143
93
Mercury 70
100
21.1
37.8
0.118
0.11
Methyl acetate 68
104
20
40
0.44
0.32 cp
Methyl iodide 68
104
20
40
0.213
0.42 cp
Menhaden oil 100
130
37.8
54.4
29.8
18.2
140
90
Milk 68 20 1.13 31.5
Molasses A, first 100
130
37.8
54.4
281-5070
151-1760
1300-23500
700-8160
Molasses B, second 100
130
37.8
54.4
1410-13200
660-3300
6535-61180
3058-15294
Molasses C, blackstrap 100
130
37.8
54.4
2630-5500
1320-16500
12190-25500
6120-76500
Naphthalene 176
212
80
100
0.9
0.78 cp
Neatstool oil 100
130
37.8
54.4
49.7
27.5
230
130
Nitrobenzene 68 20 1.67 31.8
Nonane-n 0
100
-17.8
37.8
1.728
0.807
32
Octane-n 0
100
-17.8
37.8
1.266
0.645
31.7
Olive oil 100
130
37.8
54.4
43.2
24.1
200
Palms oil 100
130
37.8
54.4
47.8
26.4
Peanut oil 100
130
37.8
54.4
42
23.4
200
Pentane-n 0
80
17.8
26.7
0.508
0.342
Petrolatum 130
160
54.4
71.1
20.5
15
100
77
Petroleum ether 60 15.6 31(est) 1.1
Phenol, carbolic acid 11.7
Propionic acid 32
68
0
20
1.52 cp
1.13
31.5
Propylene glycol 70 21.1 52 241
Quenching oil
(typical)
100-120 20.5-25
Rapeseed oil 100
130
37.8
54.4
54.1
31
250
145
Rosin oil 100
130
37.8
54.4
324.7
129.9
1500
600
Rosin (wood) 100
200
37.8
93.3
216-11M
108-4400
1M-50M
500-20M
Sesame seed oil 100
130
37.8
54.4
39.6
23
184
110
Silicate of soda 79
Sodium chloride 5% 68 20 1.097 31.1
Sodium chloride 25% 60 15.6 2.4 34
Sodium hydroxide (caustic soda) 20% 65 18.3 4.0 39.4
Sodium hydroxide (caustic soda) 30% 65 18.3 10.0 58.1
Sodium hydroxide (caustic soda) 40% 65 18.3
Soya bean oil 100
130
37.8
54.4
35.4
19.64
165
96
Sperm oil 100
130
37.5
54.4
21-23
15.2
110
78
Sulphuric acid 100% 68
140
20
60
~ 25.4 cp
~ 7.2 cp
76
Sulphuric acid 95% 68 20 ~ 17.5 cp 75
Sulphuric acid 60% 68 20 ~ 4.4 cp 41
Sulphuric acid 20% 68 20 ~1.5 cp
Tar, coke oven 70
100
21.1
37.8
600-1760
141-308
15M-300M
2M-20M
Tar, gas house 70
100
21.1
37.8
3300-66M
440-4400
2500
500
Tar, pine 100
132
37.8
55.6
559
108.2
200-300
55-60
Toluene 68
140
20
60
0.68
0.38 cp
185.7
Triethylene glycol 70 21.1 40 400-440
185-205
Turpentine 100
130
37.8
54.4
86.5-95.2
39.9-44.3
1425
650
Varnish, spar 68
100
20
37.8
313
143
Water, distilled 68 20 1.0038 31
Water, fresh
60
130
15.6
54.4
1.13
0.55
31.5
Water, sea 1.15 31.5
Whale oil 100
130
37.8
54.4
35-39.6
19.9-23.4
163-184
97-112
Xylene-o 68
104
20
40
0.93
0.623 cp
Sponsored Links

Related Topics

Fluid Mechanics

The study of fluids - liquids and gases. Involving velocity, pressure, density and temperature as functions of space and time.

Material Properties

Properties of gases, fluids and solids. Densities, specific heats, viscosities and more.

Viscosities

Viscosities of products and chemical species at varying conditions.

Related Documents

Dynamic, Absolute, and Kinematic Viscosity – Definitions & Conversions

The differences between dynamic, absolute, and kinematic viscosity - a fluids resistance to flow - with definitions, unit conversions, and practical applications for engineers and scientists.

API Gravity: Definition, Calculation, and Converter

API expresses the gravity or density of liquid petroleum products. Online API to Specific Gravity calculator.

Benzene - Dynamic and Kinematic Viscosity vs. Temperature and Pressure

Online calculator, figures and table showing dynamic and kinematic viscosity of benzene, C6H6, at varying temperature and pressure - Imperial and SI Units.

Centrifugal Pumps - Influence of Viscosity

Hydrodynamic losses through pumps depends on fluid viscosities.

Crude Oil Viscosity vs. Gravity

Viscosity at 20°C/68°F and 50°C/122°F for more than 120 crudes is shown as function of specific gravity@15°C/60°F.

Drag Coefficient

The drag coefficient quantifies the drag or resistance of an object in a fluid environment.

Dynamic (Absolute) Viscosity - Converting Chart

Convert dynamic viscosity values between units like Poiseuille - Poise - centiPoise and more.

Engine & Gear Oil - Recommended Viscosity vs. Outside Temperature

Oil viscosity vs. temperature.

Fuel Oil Burners

Pot types, gun types and rotary types fuel burners.

Fuel Oil Combustion Values

Combustion values in Btu/gal for fuel oils No.1 to No.6.

Hazen-Williams Pressure Loss Equation

The Hazen-Williams equation can be used to calculate the pressure drop (psi) or friction loss in pipes or tubes.

Industrial Lubricants - Viscosities vs. ISO-VG Grade

ISO-VG viscosity grades for industrial lubricants.

ISO Grade Oils - Viscosities and Densities

Viscosities and densities of ISO - and equivalent SAE grade oils.

Kinematic Viscosity - Unit Converter

Convert between Centistokes, Saybolt and Redwood seconds.

Laminar vs. Turbulent Flow - Reynolds Number Explained with Calculator

Introduction and definition of the dimensionless Reynolds Number - online calculators.

Laminar, Transitional and Turbulent Flow

Heat transfer, pressure and head loss in a fluid varies with laminar, transitional or turbulent flow.

Motor Oils - Dynamic Viscosities

Dynamic viscosities for motor oils SAE 10 to 50 for temperatures ranging 0-100 oC.

Oil Fuels - Viscosities vs. Temperatures

Viscosities of fuel oils vs. temperature.

Oil Pipes - Pressure Loss vs. Oil Flow

Pressure drop in oil pipes - viscosities ranging 100 - 600 Saybolt Universal Seconds.

Pipes Submerged in Oil or Fat - Heat Emission

Heat emission from steam or water heating pipes submerged in oil or fat - forced and natural circulation.

SAE Multigrade Oils - Viscosities and Densities

Viscosities and densities of SAE Grade oils.

Secondary Coolants - Properties

Comparing properties like specific gravity, freezing points and viscosity for secondary coolants like calcium chloride, sodium chloride, ethylene glycol and propylene glycol.

Steam - Viscosity vs. Pressure

Absolute viscosity of steam at pressure ranging 1 - 10000 psia.

Steel Pipes - Viscous Liquid Flow and Friction Loss

Friction loss in schedule 40 steel pipe with viscous liquids - viscosities ranging from water to oil.

Sugar Water Solutions - Viscosities

Dynamic viscosities of sucrose water solutions vs. temperature.

Viscosity Converter: Convert Between Dynamic & Kinematic Viscosity

Convert between viscosity units like Centiposes, milliPascal, CentiStokes and SSU.

Viscous Liquids - Friction Loss vs. Viscosity and Flow

Friction loss in steel pipes for fluids with viscosities ranging 32 - 80000 SSU.

Viscous Liquids - Max. Delivery Flow Velocities

Recommended max. flow velocities on delivery sides of pumps in viscous systems.

Viscous Liquids - Max. Suction Flow Velocities

Recommended max. pump suction flow velocity for viscous fluids.

Water - Absolute (Dynamic) Viscosity vs. Temperature and Pressure

Absolute viscosity for water in centipoises for temperatures between 32 - 200oF.

Water Flow in Tubes - Reynolds Number

Reynolds number for clean cold water flow.

Sponsored Links

Search Engineering ToolBox

Search is the most efficient way to navigate the Engineering ToolBox!

SketchUp Extension - Online 3D modeling!

Add standard and customized parametric components - like flange beams, lumbers, piping, stairs and more - to your Sketchup model with the Engineering ToolBox - SketchUp Extension - enabled for use with the amazing, fun and free SketchUp Make and SketchUp Pro . Add the Engineering ToolBox extension to your SketchUp from the Sketchup Extension Warehouse!

Privacy

We don't collect information from our users. Only emails and answers are saved in our archive. Cookies are only used in the browser to improve user experience.

Some of our calculators and applications let you save application data to your local computer. These applications will - due to browser restrictions - send data between your browser and our server. We don't save this data.

Google use cookies for serving our ads and handling visitor statistics on the AMP pages. Please read Google Privacy & Terms for more information about how you can control adserving and the information collected.

AddThis use cookies for handling links to social media. Please read AddThis Privacy for more information.