Torsional Shear Constant C Surface Area (in x in x in) (lbf /ft) (in) - - (in2 ) (in4 ) (in3 ) (in) (in3 ) (in4 ) (in3 ) (ft2 /ft) 32 x 32 x 5/8 259.83 0.625 48.2 48.2 76.4 12300 771 12.7 890 19700 1230 10.34 32 x 32 x 1/2 210.72 0.500 61.0 61.0 61.9 10100 634 12.8 727 15900 991 10.45 32 x 32 x 3/8 159.37 0.375 82.3 82.3 46.8 7750 485 12.9 553 12000 750 10.51 30 x 30 x 5/8 242.82 0.625 45.0 45.0 71.4 10100 673 11.9 778 16200 1070 9.68 30 x 30 x 1/2 197.11 0.500 57.0 57.0 57.9 8320 555 12.0 637 13000 869 9.79 30 x 30 x 3/8 149.16 0.375 77.0 77.0 43.8 6370 424 12.1 485 9870 658 9.84 28 x 28 x 5/8 225.80 0.625 41.8 41.8 66.4 8140 582 11.1 674 13100 933 9.01 28 x 28 x 1/2 183.50 0.500 53.0 53.0 53.9 6730 480 11.2 552 10600 755 9.12 28 x 28 x 3/8 138.95 0.375 71.7 71.7 40.8 5150 368 11.2 421 8010 572 9.17 26 x 26 x 5/8 208.79 0.625 38.6 38.6 61.4 6460 497 10.3 577 10500 801 8.34 26 x 26 x 1/2 169.89 0.500 49.0 49.0 49.9 5350 411 10.4 474 8430 649 8.45 26 x 26 x 3/8 128.74 0.375 66.3 66.3 37.8 4110 316 10.4 362 6400 492 8.51 24 x 24 x 5/8 191.78 0.625 35.4 35.4 56.4 5030 419 9.44 487 8180 679 7.68 24 x 24 x 1/2 156.28 0.500 45.0 45.0 45.9 4170 348 9.53 401 6610 551 7.79 24 x 24 x 3/8 118.53 0.375 61.0 61.0 34.8 3210 268 9.60 307 5020 418 7.84 22 x 22 x 5/8 174.76 0.625 32.2 32.2 51.4 3820 347 8.62 406 6260 567 7.01 22 x 22 x 1/2 142.67 0.500 41.0 41.0 41.9 3190 290 8.72 335 5070 461 7.12 22 x 22 x 3/8 108.32 0.375 55.7 55.7 31.8 2460 223 8.78 256 3850 350 7.17 20 x 20 x 5/8 157.75 0.625 29.0 29.0 46.4 2830 283 7.81 331 4670 465 6.34 20 x 20 x 1/2 129.06 0.500 37.0 37.0 37.9 2370 237 7.90 275 3790 379 6.45 20 x 20 x 3/8 98.12 0.375 50.3 50.3 28.8 1830 183 7.97 211 2880 288 6.51 18 x 18 x 5/8 140.73 0.625 25.8 25.8 41.4 2020 224 6.99 264 3370 373 5.68 18 x 18 x 1/2 115.45 0.500 33.0 33.0 33.9 1700 189 7.08 220 2740 305 5.79 18 x 18 x 3/8 87.91 0.375 45.0 45.0 25.8 1320 147 7.15 169 2090 232 5.84 16 x 16 x 5/8 127.37 0.581 24.5 24.5 35.0 1370 171 6.25 200 2170 276 5.17 16 x 16 x 1/2 103.30 0.465 31.4 31.4 28.3 1130 141 6.31 164 1770 224 5.20 16 x 16 x 3/8 78.52 0.349 42.8 42.8 21.5 873 109 6.37 126 1350 171 5.23 16 x 16 x 5/16 65.87 0.291 52.0 52.0 18.1 739 92.3 6.39 106 1140 144 5.25 14 x 14 x 5/8 110.36 0.581 21.1 21.1 30.3 896 128 5.44 151 1430 208 4.50 14 x 14 x 1/2 89.68 0.465 27.1 27.1 24.6 743 106 5.49 124 1170 170 4.53 14 x 14 x 3/8 68.31 0.349 37.1 37.1 18.7 577 82.5 5.55 95.4 900 130 4.57 14 x 14 x 5/16 57.36 0.291 45.1 45.1 15.7 490 69.9 5.58 80.5 759 109 4.58 12 x 12 x 5/8 93.34 0.581 17.7 17.7 25.7 548 91.3 4.62 109 885 151 3.83 12 x 12 x 1/2 76.07 0.465 22.8 22.8 20.9 457 76.2 4.68 89.6 728 123 3.87 12 x 12 x 3/8 58.10 0.349 31.4 31.4 16.0 357 59.5 4.73 69.2 561 94.6 3.90 12 x 12 x 5/16 48.86 0.291 38.2 38.2 13.4 304 50.7 4.76 58.6 474 79.7 3.92 12 x 12 x 1/4 39.43 0.233 48.5 48.5 10.8 248 41.4 4.79 47.6 384 64.5 3.93 10 x 10 x 5/8 76.33 0.581 14.2 14.2 21.0 304 60.8 3.80 73.2 498 102 3.17 10 x 10 x 1/2 62.46 0.465 18.5 18.5 17.2 256 51.2 3.86 60.7 412 84.2 3.20 10 x 10 x 3/8 47.90 0.349 25.7 25.7 13.2 202 40.4 3.92 47.2 320 64.8 3.23 10 x 10 x 5/16 40.35 0.291 31.4 31.4 11.1 172 34.5 3.94 40.1 271 54.8 3.25 10 x 10 x 1/4 32.63 0.233 39.9 39.9 8.96 141 28.3 3.97 32.7 220 44.4 3.27 10 x 10 x 3/16 24.73 0.174 54.5 54.5 6.76 108 21.6 4.00 24.8 167 33.6 3.28 9 x 9 x 1/2 55.66 0.465 16.4 16.4 15.3 182 40.6 3.45 48.4 296 67.4 2.87 9 x 9 x 3/8 42.79 0.349 22.8 22.8 11.8 145 32.2 3.51 37.8 231 52.1 2.90 9 x 9 x 5/16 36.10 0.291 27.9 27.9 9.92 124 27.6 3.54 32.1 196 44.0 2.92 9 x 9 x 1/4 29.23 0.233 35.6 35.6 8.03 102 22.7 3.56 26.2 159 35.8 2.93 9 x 9 x 3/16 22.18 0.174 48.7 48.7 6.06 78.2 17.4 3.59 20.0 121 27.1 2.95 8 x 8 x 5/8 59.32 0.581 10.8 10.8 16.4 146 36.5 2.99 44.7 244 63.2 2.50 8 x 8 x 1/2 48.85 0.465 14.2 14.2 13.5 125 31.2 3.04 37.5 204 52.4 2.53 8 x 8 x 3/8 37.69 0.349 19.9 19.9 10.4 99.6 24.9 3.10 29.4 160 40.7 2.57 8 x 8 x 5/16 31.84 0.291 24.5 24.5 8.76 85.6 21.4 3.13 25.1 136 34.5 2.58 8 x 8 x 1/4 25.82 0.233 31.3 31.3 7.10 70.7 17.7 3.15 20.5 111 28.1 2.60 8 x 8 x 3/16 19.63 0.174 43.0 43.0 5.37 54.4 13.6 3.18 15.7 84.5 21.3 2.62 7 x 7 x 5/8 50.81 0.581 9.0 9.0 14.0 93.3 26.7 2.58 33.1 158 47.1 2.17 7 x 7 x 1/2 42.05 0.465 12.1 12.1 11.6 80.5 23.0 2.63 27.9 133 39.3 2.20 7 x 7 x 3/8 32.58 0.349 17.1 17.1 8.97 64.9 18.6 2.69 22.1 105 30.7 2.23 7 x 7 x 5/16 27.59 0.291 21.1 21.1 7.59 56.1 16.0 2.72 18.9 89.7 26.1 2.25 7 x 7 x 1/4 22.42 0.233 27.0 27.0 6.17 46.5 13.3 2.75 15.5 73.5 21.3 2.27 7 x 7 x 3/16 17.08 0.174 37.2 37.2 4.67 36.0 10.3 2.77 11.9 56.1 16.2 2.28 6 x 6 x 5/8 42.30 0.581 7.3 7.3 11.7 55.1 18.4 2.17 23.2 94.9 33.4 1.83 6 x 6 x 1/2 35.24 0.465 9.9 9.9 9.74 48.2 16.1 2.23 19.8 81.1 28.1 1.87 6 x 6 x 3/8 27.48 0.349 14.2 14.2 7.58 39.4 13.1 2.28 15.8 64.6 22.1 1.90 6 x 6 x 5/16 23.34 0.291 17.6 17.6 6.43 34.3 11.4 2.31 13.6 55.4 18.9 1.92 6 x 6 x 1/4 19.02 0.233 22.8 22.8 5.24 28.6 9.54 2.34 11.2 45.6 15.4 1.93 6 x 6 x 3/16 14.53 0.174 31.5 31.5 3.98 22.3 7.42 2.37 8.63 35.0 11.8 1.95 6 x 6 x 1/8 9.86 0.116 48.7 48.7 2.70 15.5 5.15 2.39 5.92 23.9 8.03 1.97 5-1/2 x 5-1/2 x 3/8 24.93 0.349 12.8 12.8 6.88 29.7 10.8 2.08 13.1 49.0 18.4 1.73 5-1/2 x 5-1/2 x 5/16 21.21 0.291 15.9 15.9 5.85 25.9 9.43 2.11 11.3 42.2 15.7 1.75 5-1/2 x 5-1/2 x 1/4 17.32 0.233 20.6 20.6 4.77 21.7 7.90 2.13 9.32 34.8 12.9 1.77 5-1/2 x 5-1/2 x 3/16 13.25 0.174 28.6 28.6 3.63 17.0 6.17 2.16 7.19 26.7 9.85 1.78 5-1/2 x 5-1/2 x 1/8 9.01 0.116 44.4 44.4 2.46 11.8 4.30 2.19 4.95 18.3 6.72 1.80 5 x 5 x 1/2 28.43 0.465 7.8 7.8 7.88 26.0 10.4 1.82 13.1 44.6 18.7 1.53 5 x 5 x 3/8 22.37 0.349 11.3 11.3 6.18 21.7 8.67 1.87 10.6 36.1 14.9 1.57 5 x 5 x 5/16 19.08 0.291 14.2 14.2 5.26 19.0 7.61 1.90 9.16 31.2 12.8 1.58 5 x 5 x 1/4 15.62 0.233 18.5 18.5 4.30 16.0 6.41 1.93 7.61 25.8 10.5 1.60 5 x 5 x 3/16 11.97 0.174 25.7 25.7 3.28 12.6 5.03 1.96 5.89 19.9 8.08 1.62 5 x 5 x 1/8 8.16 0.116 40.1 40.1 2.23 8.80 3.52 1.99 4.07 13.7 5.53 1.63 4-1/2 x 4-1/2 x 1/2 25.03 0.465 6.7 6.7 6.95 18.0 8.02 1.61 10.2 31.3 14.8 1.37 4-1/2 x 4-1/2 x 3/8 19.82 0.349 9.9 9.9 5.48 15.3 6.78 1.67 8.36 25.7 11.9 1.40 4-1/2 x 4-1/2 x 5/16 16.96 0.291 12.5 12.5 4.68 13.5 5.99 1.70 7.27 22.3 10.2 1.42 4-1/2 x 4-1/2 x 1/4 13.91 0.233 16.3 16.3 3.84 11.4 5.08 1.73 6.06 18.5 8.44 1.43 4-1/2 x 4-1/2 x 3/16 10.70 0.174 22.9 22.9 2.93 9.02 4.01 1.75 4.71 14.4 6.49 1.45 4-1/2 x 4-1/2 x 1/8 7.31 0.116 35.8 35.8 2.00 6.35 2.82 1.78 3.27 9.92 4.45 1.47 4 x 4 x 1/2 21.63 0.465 5.6 5.6 6.02 11.9 5.95 1.41 7.70 21.0 11.2 1.20 4 x 4 x 3/8 17.27 0.349 8.5 8.5 4.78 10.3 5.13 1.46 6.39 17.5 9.14 1.23 4 x 4 x 5/16 14.83 0.291 10.7 10.7 4.10 9.14 4.57 1.49 5.59 15.3 7.91 1.25 4 x 4 x 1/4 12.21 0.233 14.2 14.2 3.37 7.80 3.90 1.52 4.69 12.8 6.56 1.27 4 x 4 x 3/16 9.42 0.174 20.0 20.0 2.58 6.21 3.10 1.55 3.67 9.96 5.07 1.28 4 x 4 x 1/8 6.46 0.116 31.5 31.5 1.77 4.40 2.20 1.58 2.56 6.91 3.49 1.30 3-1/2 x 3-1/2 x 3/8 14.72 0.349 7.0 7.0 4.09 6.48 3.70 1.26 4.69 11.2 6.77 1.07 3-1/2 x 3-1/2 x 5/16 12.70 0.291 9.0 9.0 3.52 5.84 3.34 1.29 4.14 9.89 5.90 1.08 3-1/2 x 3-1/2 x 1/4 10.51 0.233 12.0 12.0 2.91 5.04 2.88 1.32 3.50 8.35 4.92 1.10 3-1/2 x 3-1/2 x 3/16 8.15 0.174 17.1 17.1 2.24 4.05 2.31 1.35 2.76 6.56 3.83 1.12 3-1/2 x 3-1/2 x 1/8 5.61 0.116 27.2 27.2 1.54 2.90 1.66 1.37 1.93 4.58 2.65 1.13 3 x 3 x 3/8 12.17 0.349 5.6 5.6 3.39 3.77 2.51 1.05 3.25 6.64 4.74 0.90 3 x 3 x 5/16 10.58 0.291 7.3 7.3 2.94 3.45 2.30 1.08 2.90 5.94 4.18 0.92 3 x 3 x 1/4 8.81 0.233 9.9 9.9 2.44 3.02 2.01 1.11 2.48 5.08 3.52 0.93 3 x 3 x 3/16 6.87 0.174 14.2 14.2 1.89 2.46 1.64 1.14 1.97 4.03 2.76 0.95 3 x 3 x 1/8 4.75 0.116 22.9 22.9 1.30 1.78 1.19 1.17 1.40 2.84 1.92 0.97 2-1/2 x 2-1/2 x 5/16 8.45 0.291 5.6 5.6 2.35 1.82 1.45 0.879 1.88 3.20 2.74 0.75 2-1/2 x 2-1/2 x 1/4 7.11 0.233 7.7 7.7 1.97 1.63 1.30 0.908 1.63 2.79 2.35 0.77 2-1/2 x 2-1/2 x 3/16 5.59 0.174 11.4 11.4 1.54 1.35 1.08 0.937 1.32 2.25 1.86 0.78 2-1/2 x 2-1/2 x 1/8 3.90 0.116 18.6 18.6 1.07 0.998 0.798 0.965 0.947 1.61 1.31 0.80 2-1/4 x 2-1/4 x 1/4 6.26 0.233 6.7 6.7 1.74 1.13 1.00 0.805 1.28 1.96 1.85 0.68 2-1/4 x 2-1/4 x 3/16 4.96 0.174 9.9 9.9 1.37 0.952 0.847 0.835 1.04 1.60 1.48 0.70 2-1/4 x 2-1/4 x 1/8 3.48 0.116 16.4 16.4 0.96 0.712 0.633 0.863 0.755 1.15 1.05 0.72 2 x 2 x 1/4 5.41 0.233 5.6 5.6 1.51 0.745 0.745 0.703 0.964 1.31 1.41 0.60 2 x 2 x 3/16 4.32 0.174 8.5 8.5 1.19 0.640 0.640 0.732 0.797 1.09 1.14 0.62 2 x 2 x 1/8 3.05 0.116 14.2 14.2 0.84 0.486 0.486 0.761 0.584 0.796 0.817 0.63 1-3/4 x 1-3/4 x 3/16 3.68 0.174 7.1 7.1 1.02 0.405 0.462 0.630 0.585 0.699 0.844 0.53 1-5/8 x 1-5/8 x 3/16 3.36 0.174 6.3 6.3 0.93 0.312 0.384 0.579 0.491 0.544 0.712 0.49 1-5/8 x 1-5/8 x 1/8 2.42 0.116 11.0 11.0 0.67 0.246 0.302 0.608 0.370 0.410 0.522 0.51 1-1/2 x 1-1/2 x 3/16 3.04 0.174 5.6 5.6 0.84 0.235 0.314 0.528 0.406 0.414 0.592 0.45 1-1/2 x 1-1/2 x 1/8 2.20 0.116 9.9 9.9 0.61 0.188 0.251 0.556 0.309 0.316 0.438 0.47 1-1/4 x 1-1/4 x 3/16 2.40 0.174 4.2 4.2 0.67 0.121 0.194 0.425 0.259 0.218 0.383 0.37 1-1/4 x 1-1/4 x 1/8 1.78 0.116 7.8 7.8 0.49 0.101 0.162 0.454 0.204 0.174 0.292 0.38 1)
b - nominal width minus 3 times the design wall thickness t t - design wall thickness h - nominal depth minus 3 times the design wall thickness t I - moment of inertia of cross-section S - elastic section modulus r - radius of gyration Z - plastic section modulus 2) Note that the cross sectional areas are calculated for sections with rounded corners (outside corner radii equal to 2 times the design wall thickness).
3) Note that nominal thickness may not be the same as actual thickness. Actual thickness may vary with manufacturing methods.
Sponsored Links
Related Topics Deflection and stress, moment of inertia, section modulus and technical information of beams and columns.
Related Documents American Standard Beams ASTM A6 - Imperial units.
Dimensions and static parameters of American Standard Steel C Channels
American Wide Flange Beams ASTM A6 in metric units.
Calculate beam load and supporting forces.
Stress, deflections and supporting loads.
Supporting loads, moments and deflections.
Supporting loads, stress and deflections.
Properties of British Universal Steel Columns and Beams.
Maximum reaction forces, deflections and moments - single and uniform loads.
Factors of Safety - FOS - are important in engineering designs.
Properties of HE-A profiled steel beams.
Shear Modulus (Modulus of Rigidity) is the elasticity coefficient for shearing or torsion force.
Radius of gyration describes the distribution of cross sectional area in columns around their centroidal axis.
Weight, cross sectional area, moments of inertia - Imperial units
Weight, cross sectional area, moments of inertia - Imperial units
Dimensions and static parameters of steel angles with equal legs - metric units.
Dimensions and static parameters of steel angles with unequal legs - imperial units.
Dimensions and static parameters of steel angles with unequal legs - metric units.
Allowable concentric loads for steel pipe columns.
Dimensions of American Wide Flange Beams ASTM A6 (or W-Beams) - Imperial units.
Young's Modulus (or Tensile Modulus alt. Modulus of Elasticity) and Ultimate Tensile Strength and Yield Strength for materials like steel, glass, wood and many more.
Sponsored Links
Search Engineering ToolBox
the most efficient way to navigate the Engineering ToolBox! About Engineering ToolBox! We don't collect information from our users. Only emails and answers are saved in our archive. Cookies are only used in the browser to improve user experience.
Some of our calculators and applications let you save application data to your local computer. These applications will - due to browser restrictions - send data between your browser and our server. We don't save this data.
Google use cookies for serving our ads and handling visitor statistics. Please read Google Privacy & Terms for more information about how you can control adserving and the information collected.
AddThis use cookies for handling links to social media. Please read AddThis Privacy for more information.
≡