Electrical Motors - Frame Dimensions

Sponsored Links

Dimensions of electrical motor frames according NEMA 1984 are indicated below:

  • 1 in (inch) = 25.4 mm
Electrical Motors - NEMA Frame Dimensions
NEMA Frame DesignationFrame Dimensions (inches)
DE2FBAN-WVU
42 2 5/8 1 3/4 1 11/16 2 1/16 1 1/8   3/8
42C 2 5/8 1 3/4 1 11/16 2 1/16 1 1/8   3/8
48 3 2 1/8 2 3/4 2 1/2 1 1/2   1/2
48C 3 2 1/8 2 3/4 2 1/2 1 1/2   1/2
48H 3 2 1/8 4 3/4 2 1/2 1 1/2   1/2
56 3 1/2 2 7/16 3 2 3/4 1 7/8   5/8
56C 3 1/2 2 7/16   2 3/4 1 7/8   5/8
56H 3 1/2 2 7/16 5 2 3/4 1 7/8   5/8
56HZ 3 1/2 2 7/16 5 2 3/4 2 1/4 2 7/8
56J 3 1/2 2 7/16   2 3/4 2 7/16   5/8
66 4 1/8 2 15/16 5 3 1/8 2 1/4   3/4
               
140T 3 1/2 2 3/4 4 2 3/4 2 1/4   7/8
142AT 3 1/2 2 3/4 3 1/4 2 3/4 1 3/4 1 1/2 7/8
143AT 3 1/2 2 3/4 4 2 1/4 1 3/4 1 1/2 7/8
143JM 3 1/2 2 3/4 4 2 1/4     7/8
143JP 3 1/2 2 3/4 4 2 1/4     7/8
143T 3 1/2 2 3/4 4 2 1/4 2 1/4 2 7/8
143TC 3 1/2 2 3/4 4 2 3/4 2 1/4   7/8
143TR 3 1/2 2 3/4 4 2 1/4 2 5/8 1 3/4 7/8
144AT 3 1/2 2 3/4 4 1/2 2 3/4 1 3/4 1 1/2 7/8
145AT 3 1/2 2 3/4 5 2 3/4 1 3/4 1 1/2 7/8
145JM 3 1/2 2 3/4 5 2 1/4     7/8
145JP 3 1/2 2 3/4 5 2 1/4     7/8
145T 3 1/2 2 3/4 5 2 1/4 2 1/4 2 7/8
145TC 3 1/2 2 3/4 5 2 3/4 2 1/4   7/8
145TR 3 1/2 2 3/4 5 2 1/4 2 5/8 1 3/4 7/8
146AT 3 1/2 2 3/4 5 1/2 2 3/4 1 3/4 1 1/2 7/8
146ATC 3 1/2 2 3/4 5 1/2 2 3/4 2 1/4   7/8
147AT 3 1/2 2 3/4 6 1/4 2 3/4 1 3/4 1 1/2 7/8
148AT 3 1/2 2 3/4 7 2 3/4 1 3/4 1 1/2 7/8
149AT 3 1/2 2 3/4 8 2 3/4 1 3/4 1 1/2 7/8
1410AT 3 1/2 2 3/4 9 2 3/4 1 3/4 1 1/2 7/8
1411AT 3 1/2 2 3/4 10 2 3/4 1 3/4 1 1/2 7/8
1412AT 3 1/2 2 3/4 11 2 3/4 1 3/4 1 1/2 7/8
1412ATC 3 1/2 2 3/4 11 2 3/4 2 1/4   7/8
162AT 4 3 1/8 4 2 1/2 1 3/4 1 1/2 7/8
163AT 4 3 1/8 4 1/2 2 1/2 1 3/4 1 1/2 7/8
164AT 4 3 1/8 2 1/2 2 1/2 1 3/4 1 1/2 7/8
165AT 4 3 1/8 5 1/22 1/2 2 1/2 1 3/4 1 1/2 7/8
166AT 4 3 1/8 6 1/4 2 1/2 1 3/4 1 1/2 7/8
167AT 4 3 1/8 7 2 1/2 1 3/4 1 1/2 7/8
168AT 4 3 1/8 8 2 1/2 1 3/4 1 1/2 7/8
169AT 4 3 1/8 9 2 1/2 1 3/4 1 1/2 7/8
1610AT 4 3 1/8 10 2 1/2 1 3/4 1 1/2 7/8
182 4 1/2 3 3/4 4 1/2 2 3/4 2 1/4 2 7/8
L182ACY 4 1/2 3 3/4 4 1/2 2 3/4 2 1/4 2 7/8
182AT 4 1/2 3 3/4 4 1/2 2 3/4 2 1/4 2 1 1/8
L182AT 4 1/2 3 3/4 4 1/2 2 3/4   2 1 1/8
182JM 4 1/2 3 3/4 4 1/2 2 3/4     7/8
182JP 4 1/2 3 3/4 4 1/2 2 3/4 2 3/4   7/8
182T 4 1/2 3 3/4 4 1/2 2 3/4 2 3/4 2 1/2 1 1/8
182TC 4 1/2 3 3/4 4 1/2 2 3/4 2 3/4   1 1/8
182TR 4 1/2 3 3/4 4 1/2 2 3/4 2 1/4 2 1/4 1 1/8
183AT 4 1/2 3 3/4 5 2 3/4 2 1/4 2 1 1/8
184 4 1/2 3 3/4 5 1/2 2 3/4 2 1/4 2 7/8
184AT 4 1/2 3 3/4 5 1/2 2 3/4 2 1/4 2 1 1/8
184JM 4 1/2 3 3/4 5 1/2 2 3/4     7/8
184JP 4 1/2 3 3/4 5 1/2 2 3/4     7/8
184TC 4 1/2 3 3/4 5 1/2 2 3/4 2 3/4   1 1/8
184T 4 1/2 3 3/4 5 1/2 2 3/4 2 3/4 2 1/2 1 1/8
184TR 4 1/2 3 3/4 5 1/2 2 3/4 3 3/8 2 1/4 1 1/8
185AT 4 1/2 3 3/4 6 1/4 2 3/4 2 1/4 2 1 1/8
186ACY 4 1/2 3 3/4 7 2 3/4 2 1/4 2 7/8
186AT 4 1/2 3 3/4 7 2 3/4 2 1/4 2 1 1/8
L186AT 4 1/2 3 3/4 7 2 3/4 2 1/4 2 1 1/8
186ATC 4 1/2 3 3/4 7 2 3/4 2 1/4   1 1/8
187AT 4 1/2 3 3/4 8 2 3/4 2 1/4 2 1 1/8
188AT 4 1/2 3 3/4 9 2 3/4 2 1/4 2 1 1/8
189AT 4 1/2 3 3/4 10 2 3/4 2 1/4 2 1 1/8
189ATC 4 1/2 3 3/4 10 2 3/4 2 1/4   1 1/8
1810AT 4 1/2 3 3/4 11 2 3/4 2 1/4 2 1 1/8
               
203 5 4 5 1/2 3 1/8 2 1/4 2 3/4
204 5 4 6 1/4 3 1/8 2 1/4 2 3/4
213 5 1/4 4 1/4 5 1/2 3 1/2 3 2 3/4 1 1/8
213AT 5 1/4 4 1/4 5 1/2 3 1/2 2 3/4 2 1/2 1 3/8
213JM 5 1/4 4 1/4 5 1/2 3 1/2     7/8
213JP 5 1/4 4 1/4 5 1/2 3 1/2     1 1/4
213T 5 1/4 4 1/4 5 1/2 3 1/2 3 3/8 3 1/8 1 3/8
213TC 5 1/4 4 1/4 5 1/2 3 1/2 3 3/8   1 3/8
213TR 5 1/4 4 1/4 5 1/2 3 1/2 4 1/8 2 5/8 1 3/8
214AT 5 1/4 4 1/4 6 1/4 3 1/2 2 3/4 2 1/2 1 3/8
215 5 1/4 4 1/4 7 3 1/2 3 2 3/4 1 1/8
215AT 5 1/4 4 1/4 7 3 1/2 2 3/4 2 1/2 1 3/8
215JM 5 1/4 4 1/4 7 3 1/2     7/8
215JP 5 1/4 4 1/4 7 3 1/2     1 1/4
215T 5 1/4 4 1/4 7 3 1/2 3 3/8 3 1/8 1 3/8
215TC 5 1/4 4 1/4 7 3 1/2 3 3/8   1 3/8
215TR 5 1/4 4 1/4 7 3 1/2 4 1/8 2 5/8 1 3/8
216AT 5 1/4 4 1/4 8 3 1/2 2 3/4 2 1/2 1 3/8
217AT 5 1/4 4 1/4 9 3 1/2 2 3/4 2 1/2 1 3/8
218AT 5 1/4 4 1/4 10 3 1/2 2 3/4 2 1/2 1 3/8
219AT 5 1/4 4 1/4 11 3 1/2 2 3/4 2 1/2 1 3/8
219ATC 5 1/4 4 1/4 11 3 1/2 2 3/4   1 3/8
2110AT 5 1/4 4 1/4 12 1/2 3 1/2 2 3/4 2 1/2 1 3/8
2110ATC 5 1/4 4 1/4 12 1/2 3 1/2 2 3/4   1 3/8
224 5 1/2 4 1/2 6 3/4 3 1/2 3 2 3/4 1
225 5 1/2 4 1/2 7 1/2 3 1/2 3 2 3/4 1
253AT 6 1/4 5 7 4 1/4 3 1/4 3 1 5/8
254 6 1/4 5 8 1/4 4 1/4 3 3/8 3 1/8 1 1/8
254AT 6 1/4 5 8 1/4 4 1/4 3 1/4 3 1 5/8
254T 6 1/4 5 8 1/4 4 1/4 4 3 3/4 1 5/8
254TC 6 1/4 5 8 1/4 4 1/4 4   1 5/8
254TR 6 1/4 5 8 1/4 4 1/4 4 1/2 2 7/8 1 5/8
254U 6 1/4 5 8 1/4 4 1/4 3 3/4 3 1/2 1 5/8
255AT 6 1/4 5 9 4 1/4 3 1/4 3 1 5/8
256AT 6 1/4 5 10 4 1/4 3 1/4 3 1 5/8
256T 6 1/4 5 10 4 1/4 4 3 3/4 1 5/8
256TC 6 1/4 5 10 4 1/4 4   1 5/8
256TR 6 1/4 5 10 4 1/4 4 1/2 2 7/8 1 5/8
256U 6 1/4 5 10 4 1/4 3 3/4 3 1/2 1 3/8
257AT 6 1/4 5 11 4 1/4 3 1/4 3 1 5/8
258AT 6 1/4 5 12 1/2 4 1/4 3 1/4 3 1 5/8
259AT 6 1/4 5 14 4 1/4 3 1/4 3 1 5/8
283AT 7 5 1/2 8 4 3/4 3 1/4 3 1/2 1 7/8
284 7 5 1/2 9 1/2 4 3/4 3 3/4 3 1/2 1 1/4
284AT 7 5 1/2 9 1/2 4 3/4 3 3/4 3 1/2 1 7/8
284T 7 5 1/2 9 1/2 4 3/4 4 5/8 4 3/8 1 7/8
284TC 7 5 1/2 9 1/2 4 3/4 4 5/8   1 7/8
284TR 7 5 1/2 9 1/2 4 3/4 4 3/4 3 1/8 1 7/8
284TC 7 5 1/2 9 1/2 4 3/4 3 1/4 3 1 5/8
284U 7 5 1/2 9 1/2 4 3/4 4 7/8 4 5/8 1 5/8
285AT 7 5 1/2 10 4 3/4 3 3/4 3 1/2 1 7/8
286AT 7 5 1/2 11 4 3/4 3 3/4 3 1/2 1 7/8
286T 7 5 1/2 11 4 3/4 4 5/8 4 3/8 1 7/8
286TC 7 5 1/2 11 4 3/4 4 5/8   1 7/8
286TR 7 5 1/2 11 4 3/4 4 3/4 3 1/8 1 7/8
286TS 7 5 1/2 11 4 3/4 3 1/4 3 1 7/8
286U 7 5 1/2 11 4 3/4 4 7/8 4 5/8 1 7/8
287AT 7 5 1/2 12 1/2 4 3/4 3 3/4 3 1/2 1 7/8
288AT 7 5 1/2 14 4 3/4 3 3/4 3 1/2 1 7/8
289AT 7 5 1/2 16 4 3/4 3 3/4 3 1/2 1 7/8
               
323AT 8 6 1/4 9 4 3/4 4 1/4 4 2 1/8
324 8 6 1/4 10 1/2 5 1/4 4 7/8 4 5/8 1 5/8
324AT 8 6 1/4 10 1/2 5 1/4 4 1/4 4 2 1/8
324TR 8 6 1/4 10 1/2 5 1/4 5 1/4 3 1/2 2 1/8
324TS 8 6 1/4 10 1/2 5 1/4 3 3/4 3 1/2 1 7/8
324U 8 6 1/4 10 1/2 5 1/4 5 5/8 5 3/8 1 7/8
325AT 8 6 1/4 11 5 1/4 4 1/4 4 2 1/8
326 8 6 1/4 12 5 1/4 4 7/8 4 5/8 1 5/8
326AT 8 6 1/4 12 5 1/4 4 1/4 4 2 1/8
326T 8 6 1/4 12 5 1/4 5 1/4 5 2 1/8
326TR 8 6 1/4 12 5 1/4 5 1/4 3 1/2 2 1/8
326TS 8 6 1/4 12 5 1/4 3 3/4 3 1/2 1 7/8
326U 8 6 1/4 12 5 1/4 5 5/8 5 3/8 1 7/8
327AT 8 6 1/4 14 5 1/4 4 1/4 4 2 1/8
328AT 8 6 1/4 16 5 1/4 4 1/4 4 2 1/8
329AT 8 6 1/4 18 5 1/4 4 1/4 4 2 1/8
363AT 9 7 10 5 7/8 4 3/4 4 1/2 2 3/8
364 9 7 11 1/4 5 7/8 5 5/8 5 3/8 1 7/8
364AT 9 7 11 1/4 5 7/8 4 3/4 4 1/2 2 3/8
364S 9 7 11 1/4 5 7/8 3 1/4 3 1 5/8
364T 9 7 11 1/4 5 7/8 5 7/8 5 7/8 2 3/8
364TR 9 7 11 1/4 5 7/8 5 3/4 3 3/4 2 3/8
364TS 9 7 11 1/4 5 7/8 3 3/4 3 1/2 1 7/8
364U 9 7 11 1/4 5 7/8 6 3/8 6 1/8 2 1/8
365 9 7 12 1/4 5 7/8 5 5/8 5 3/8 1 7/8
365AT 9 7 12 1/4 5 7/8 4 3/4 4 1/2 2 3/8
365T 9 7 12 1/4 5 7/8 5 7/8 4 7/8 2 3/8
324T 8 6 1/4 10 1/2 5 1/4 5 1/4 5 2 1/8
365TR 9 7 12 1/4 5 7/8 5 3/4 3 3/4 2 3/8
365TS 9 7 12 1/4 5 7/8 3 3/4 3 1/2 1 7/8
365U 9 7 12 1/4 5 7/8 6 3/8 6 1/8 2 1/8
366AT 9 7 14 5 7/8 4 3/4 4 1/2 2 3/8
364AT 9 7 11 1/4 5 7/8 4 3/4 4 1/2 2 3/8
367AT 9 7 16 5 7/8 4 3/4 4 1/2 2 3/8
368AT 9 7 18 5 7/8 4 3/4 4 1/2 2 3/8
369AT 9 7 20 5 7/8 4 3/4 4 1/2 2 3/8
  • 1 inch = 25.4 mm
Sponsored Links

Related Topics

Electrical

Electrical units, amps and electrical wiring, wire gauge and AWG, electrical formulas and motors.

Related Documents

Electric Motor Calculator

Calculate amps, hp and kVA for electrical motors.

Electric Motors - Efficiency

Calculate electric motor efficiency.

Electric Motors - IEC and NEMA Standard Torques

IEC and NEMA torque classifications of electrical motors.

Electrical Induction Motors - Synchronous Speed

Operating speed of an induction motor depends on the input power frequency and the number of magnetic poles in the motor.

Electrical Motors - Full Load Amps

Full load amps for single and 3-phase 460 volts, 230 volts and 115 volts electric motors.

Electrical Motors - Locked Rotor Design Code Letters

NEMA locked rotor indicating code letters for electrical motors.

Electrical Motors - NEMA Frame Assignments

NEMA frame assignments.

Electrical Motors - Shaft Power vs. Voltage and Current

Calculate electric motors shaft power.

Electrical Motors Efficiency Ratings

NEMA - electrical motor efficiency ratings.

NEMA - National Electrical Manufacturers Association

National Electrical Manufacturers Association.

NEMA A, B, C and D Electrical Motor Design

NEMA has established the four different designs A, B, C and D for electrical induction motors.

NEMA Enclosure Standards for Electric Motors

NEMA enclosure standard for electrical motors.

NEMA Insulation Classes

Electrical insulation systems rated by standard NEMA classifications to maximize allowable operating temperatures.

Nema Starters

Nema sized contactors or starters.

Three-Phase Electrtical Motors - Power Factor vs. Inductive Load

Inductive loads and power factors with electrical three-phase motors.

Sponsored Links

Search Engineering ToolBox

  • the most efficient way to navigate the Engineering ToolBox!

SketchUp Extension - Online 3D modeling!

Add standard and customized parametric components - like flange beams, lumbers, piping, stairs and more - to your Sketchup model with the Engineering ToolBox - SketchUp Extension - enabled for use with the amazing, fun and free SketchUp Make and SketchUp Pro . Add the Engineering ToolBox extension to your SketchUp from the Sketchup Extension Warehouse!

Privacy

We don't collect information from our users. Only emails and answers are saved in our archive. Cookies are only used in the browser to improve user experience.

Some of our calculators and applications let you save application data to your local computer. These applications will - due to browser restrictions - send data between your browser and our server. We don't save this data.

Google use cookies for serving our ads and handling visitor statistics. Please read Google Privacy & Terms for more information about how you can control adserving and the information collected.

AddThis use cookies for handling links to social media. Please read AddThis Privacy for more information.