Compressed Air Pipe Lines - Pressure Loss vs. Capacity and Operating Pressure

Sponsored Links

Pressure drop in a compressed air pipe line depends on line pressure, air flow and size of pipe.

Pressure Loss in Schedule 40 Steel Pipes

Compressed Air Pipe Lines - Pressure Loss vs. Capacity and Operating Pressure
NPS
(in)
Air Flow1)
(SCFM)

Pressure Loss per 100 ft pipe (psi)
Line Pressure (psig)
5075100125
1/2 10 0.7 0.5 0.4 0.3
20 2.7 2.0 1.6 1.3
30 5.9 4.3 3.4 2.8
40 7.5 5.8 4.8
50 9.0 7.4
60 12.9 10.6
3/4 10 0.2 0.15
20 0.9 0.5 0.4 0.3
50 3.8 2.7 2.1 1.8
80 6.8 5.2 4.4
100 10.6 8.3 7.0
125 12.9 10.7
150 13.9
1 20 0.2 0.1 0.1
50 1.1 0.8 0.6 0.5
75 2.6 1.7 1.3 1.1
100 4.1 3.0 2.3 1.9
125 6.3 4.5 3.5 2.9
150 6.5 5.1 4.2
200 8.9 7.3
250 11.3
1 1/2 50 0.1
75 0.3 0.2 0.15 0.1
100 0.5 0.3 0.3 0.2
125 0.7 0.5 0.4 0.3
150 1.0 0.8 0.6 0.5
200 1.8 1.3 1.0 0.8
250 2.8 2.0 1.6 1.3
300 4.0 2.9 2.3 1.9
400 7.0 5.0 4.0 3.2
500 7.8 6.2 5.1
600 8.8 7.2
700 11.9 9.8
800 12.8
2 100 0.1
150 0.3 0.2 0.2 0.1
200 0.5 0.4 0.3 0.2
250 0.8 0.6 0.4 0.4
300 1.1 0.8 0.6 0.5
400 1.9 1.4 1.1 0.9
500 2.9 2.1 1.7 1.4
600 4.2 3.0 2.4 2.0
800 5.4 4.2 3.4
1000 8.3 6.5 5.3
1250 10.0 8.3
1500 11.9
2 1/2 150 0.1
200 0.2 0.15 0.1
250 0.3 0.2 0.2 0.1
300 0.5 0.3 0.3 0.2
400 0.8 0.6 0.5 0.4
500 1.2 0.9 0.4 0.6
600 1.7 1.3 1.0 0.8
800 3.0 2.2 1.7 1.4
1000 4.7 3.4 2.7 1.9
1250 7.5 5.4 4.2 3.5
1500 7.5 5.9 4.8
2000 10.3 8.5
2500 13.3
3 300 0.1 0.1
500 0.4 0.3 0.2 0.2
750 0.8 0.6 0.5 0.4
1000 1.5 1.1 0.8 0.7
1500 3.3 2.4 1.9 1.5
2000 5.9 4.2 3.3 2.7
2500 5.6 5.1 4.2
3000 9.4 7.4 5.1
3500 10.1 8.3
4000 13.1 10.8
4500 13.6
4 750 0.2 0.15 0.1
1000 0.4 0.3 0.2 0.2
1500 0.8 0.6 0.5 0.4
2000 1.5 1.1 0.8 0.7
2500 2.2 1.6 1.3 1.1
3000 3.2 2.3 1.8 1.5
4000 5.7 3.4 3.2 2.6
5000 6.3 5.0 4.1
6000 9.0 7.1 6.8
7000 9.7 7.9
8000 12.7 10.3

1) Free Air Inflow Volume Flow at Standard Conditions

Related Mobile Apps from The Engineering ToolBox

- free apps for offline use on mobile devices.

Sponsored Links

Related Topics

Gases and Compressed Air

Properties of air, LNG, LPG and other common gases. Pipeline capacities and sizing of relief valves.

Related Documents

Compressed Air - Air Flow and Recommended Pipe Size

Pipe line sizing compressed air

Compressed Air - Friction Loss in Hoses

Friction loss in air hoses vs. operating pressure.

Compressed Air - Laboratory Consumption

Compressed air supply to laboratories.

Compressed Air - Pipe Line Pressure Drop Diagram

Calculate pressure drop in compressed air pipe lines with a nomograph diagram.

Compressed Air - Pipe Line Pressure Loss - Online Calculator with Metric and Imperial Units

Calculate pressure drop in compressed air pipe lines - metric and imperial units.

Compressed Air - Pressure Drop Diagrams, Metric Units

Pressure loss in compressed air pipe lines.

Compressed Air - Size of Pipe vs. Capacity

Air pipe lines capacities at pressure 100 psi (6.9 bar).

Compressed Air Pipe Line Capacity

Capacities of compressed air pipelines - pressure ranging 5 - 250 psi (0.5 - 17 bar).

Compressed Air Piping - Pressure Loss Diagrams, Imperial Units

Pressure drop in compressed air pipelines with applied pressure 50, 100 and 150 psi.

Compressed Air vs. Free Air - Compression Ratio

The ratio of compressed air pressure to free air pressure.

Horsepower required to Compress Air

Calculate horsepower required by air compressors.

Sponsored Links

Search Engineering ToolBox

Search is the most efficient way to navigate the Engineering ToolBox!

SketchUp Extension - Online 3D modeling!

Add standard and customized parametric components - like flange beams, lumbers, piping, stairs and more - to your Sketchup model with the Engineering ToolBox - SketchUp Extension - enabled for use with the amazing, fun and free SketchUp Make and SketchUp Pro . Add the Engineering ToolBox extension to your SketchUp from the Sketchup Extension Warehouse!

Privacy

We don't collect information from our users. Only emails and answers are saved in our archive. Cookies are only used in the browser to improve user experience.

Some of our calculators and applications let you save application data to your local computer. These applications will - due to browser restrictions - send data between your browser and our server. We don't save this data.

Google use cookies for serving our ads and handling visitor statistics on the AMP pages. Please read Google Privacy & Terms for more information about how you can control adserving and the information collected.

AddThis use cookies for handling links to social media. Please read AddThis Privacy for more information.