EN 1329 - PVC Piping for Soil and Waste Discharge - Dimensions
Dimensions of PVC pipes according EN 1329.
Dimensions of EN 1329 Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure. Unplasticized poly(vinyl chloride) (PVC-U):
Metric Series
| Nominal Size (mm) | Nominal Outside Diameter (mm) | Mean Outside Diameter (mm) | |
|---|---|---|---|
| min | max | ||
| 32 | 32 | 32.0 | 32.2 |
| 40 | 40 | 40.0 | 40.2 |
| 50 | 50 | 50.0 | 50.2 |
| 63 | 63 | 63.0 | 63.2 |
| 75 | 75 | 75.0 | 75.3 |
| 80 | 80 | 80.0 | 80.3 |
| 82 | 82 | 82.0 | 82.3 |
| 90 | 90 | 90.0 | 90.3 |
| 100 | 100 | 1000.0 | 100.3 |
| 110 | 110 | 110.0 | 110.3 |
| 125 | 125 | 125.0 | 125.3 |
| 140 | 140 | 140.0 | 140.4 |
| 160 | 160 | 160.0 | 160.4 |
| 180 | 180 | 180.0 | 180.4 |
| 200 | 200 | 200.0 | 200.5 |
| 250 | 250 | 250.0 | 250.5 |
| 315 | 315 | 315.0 | 315.6 |
Inch based Series
| Nominal Size (mm) | Nominal Outside Diameter (mm) | Mean Outside Diameter (mm) | |
|---|---|---|---|
| min | max | ||
| 36 | 36 | 36.2 |
36.5 |
| 43 | 43 | 42.8 | 43.1 |
| 56 | 56 | 55.8 | 56.1 |