Condensate Pipe Lines - Sizing
When sizing condensate return lines in steam distribution system - remember that the maximum condensate flow is achieved during plant start up when pipes and equipment are heated up.
A rule of thumb - the condensate load used to design condensate pipe lines should be twice the maximum production load.
Pressure loss | Condensate Flow (kg/hour) | ||||||||
---|---|---|---|---|---|---|---|---|---|
Pipe Size (mm, inch) | |||||||||
15 | 20 | 25 | 32 | 40 | 50 | 65 | 80 | ||
(Pa/m) | (mbar/m) | 1/2 | 3/4 | 1 | 1 1/4 | 1 1/2 | 2 | 2 1/2 | 3 |
28 | 0.28 | 90 | 209 | 380 | 865 | 1320 | 2554 | 5194 | 8079 |
29 | 0.29 | 92 | 214 | 400 | 878 | 1340 | 2590 | 5271 | 8196 |
30 | 0.3 | 93 | 218 | 403 | 890 | 1361 | 2631 | 5348 | 8314 |
33 | 0.33 | 97 | 226 | 414 | 930 | 1420 | 2744 | 5579 | 8677 |
39 | 0.39 | 107 | 249 | 469 | 1028 | 1565 | 3025 | 6142 | 9526 |
40 | 0.4 | 108 | 253 | 476 | 1040 | 1583 | 3062 | 6214 | 9639 |
43 | 0.43 | 113 | 263 | 496 | 1079 | 1646 | 3180 | 6454 | 10024 |
45 | 0.45 | 116 | 270 | 508 | 1107 | 1687 | 3261 | 6618 | 10297 |
47 | 0.47 | 119 | 277 | 521 | 1134 | 1728 | 3338 | 6777 | 10523 |
50 | 0.5 | 123 | 286 | 538 | 1172 | 1787 | 3447 | 6949 | 10859 |
53 | 0.53 | 127 | 296 | 557 | 1211 | 1846 | 3565 | 7235 | 11249 |
55 | 0.55 | 130 | 302 | 569 | 1238 | 1887 | 3638 | 7380 | 11476 |
57 | 0.57 | 133 | 308 | 580 | 1261 | 1923 | 3710 | 7525 | 11703 |
59 | 0.59 | 135 | 314 | 591 | 1288 | 1959 | 3783 | 7666 | 11884 |
61 | 0.61 | 138 | 320 | 602 | 1311 | 1996 | 3851 | 7806 | 12111 |
64 | 0.64 | 141 | 327 | 615 | 1338 | 2041 | 3933 | 7970 | 12383 |
67 | 0.67 | 146 | 337 | 634 | 1379 | 2100 | 4051 | 8210 | 12746 |
69 | 0.69 | 148 | 343 | 645 | 1402 | 2136 | 4119 | 8342 | 12973 |
71 | 0.71 | 150 | 348 | 655 | 1424 | 2168 | 4182 | 8473 | 13154 |
73 | 0.73 | 152 | 354 | 665 | 1447 | 2200 | 4246 | 8600 | 13336 |
76 | 0.76 | 155 | 359 | 675 | 1465 | 2236 | 4305 | 8723 | 13563 |
77 | 0.77 | 157 | 365 | 685 | 1488 | 2268 | 4368 | 8850 | 13744 |
78 | 0.78 | 158 | 366 | 689 | 1497 | 2282 | 4390 | 8900 | 13812 |
80 | 0.8 | 160 | 370 | 695 | 1510 | 2300 | 4427 | 8972 | 13925 |
82 | 0.82 | 162 | 375 | 704 | 1529 | 2331 | 4491 | 9072 | 14407 |
88 | 0.88 | 168 | 391 | 733 | 1590 | 2427 | 4536 | 9453 | 14651 |
90 | 0.9 | 170 | 395 | 740 | 1606 | 2449 | 4717 | 9548 | 14787 |
98 | 0.98 | 179 | 414 | 777 | 1696 | 2567 | 4944 | 10025 | 15513 |
100 | 1 | 180 | 418 | 785 | 1701 | 2590 | 4990 | 10115 | 15649 |
114 | 1.14 | 194 | 450 | 845 | 1832 | 2790 | 5366 | 10841 | 16828 |
118 | 1.18 | 198 | 457 | 857 | 1860 | 2830 | 5443 | 11022 | 17055 |
120 | 1.2 | 199 | 462 | 867 | 1880 | 2860 | 5502 | 11113 | 17282 |
131 | 1.31 | 209 | 484 | 907 | 1969 | 2994 | 5761 | 11657 | 18053 |
137 | 1.37 | 215 | 497 | 931 | 2018 | 3071 | 5906 | 11948 | 18507 |
140 | 1.4 | 216 | 502 | 939 | 2037 | 3103 | 5965 | 12066 | 18688 |
147 | 1.47 | 224 | 516 | 966 | 2096 | 3189 | 6128 | 12383 | 19187 |
157 | 1.57 | 231 | 534 | 1002 | 2168 | 3298 | 6337 | 12814 | 19822 |
160 | 1.6 | 234 | 541 | 1011 | 2195 | 3340 | 6409 | 12973 | 20049 |
163 | 1.63 | 237 | 546 | 1025 | 2218 | 3370 | 6477 | 13109 | 20276 |
176 | 1.76 | 246 | 570 | 1066 | 2309 | 3511 | 6740 | 13608 | 21092 |
180 | 1.8 | 249 | 576 | 1075 | 2331 | 3547 | 6808 | 13744 | 21319 |
196 | 1.96 | 261 | 603 | 1129 | 2440 | 3710 | 7130 | 14379 | 22317 |
200 | 2 | 265 | 611 | 1143 | 2472 | 3760 | 7221 | 14560 | 22589 |
212 | 2.12 | 273 | 629 | 1179 | 2549 | 3874 | 7430 | 15014 | 23270 |
216 | 2.16 | 275 | 634 | 1188 | 2567 | 3905 | 7493 | 15132 | 23451 |
220 | 2.2 | 278 | 641 | 1200 | 2595 | 3942 | 7570 | 15277 | 23678 |
229 | 2.29 | 284 | 655 | 1225 | 2649 | 4028 | 7729 | 15604 | 24177 |
235 | 2.35 | 288 | 664 | 1243 | 2689 | 4086 | 7843 | 15840 | 24522 |
240 | 2.4 | 292 | 672 | 1256 | 2719 | 4129 | 7927 | 16017 | 24780 |
245 | 2.45 | 295 | 679 | 1270 | 2749 | 4173 | 8010 | 16193 | 25039 |
255 | 2.55 | 301 | 694 | 1297 | 2806 | 4260 | 8176 | 16520 | 25556 |
260 | 2.6 | 304 | 701 | 1311 | 2834 | 4304 | 8260 | 16683 | 25814 |
261 | 2.61 | 305 | 703 | 1315 | 2844 | 4318 | 8287 | 16738 | 25900 |
274 | 2.74 | 313 | 721 | 1348 | 2917 | 4331 | 8501 | 17173 | 26554 |
277 | 2.77 | 315 | 727 | 1356 | 2935 | 4459 | 8555 | 17282 | 26717 |
280 | 2.8 | 317 | 730 | 1363 | 2948 | 4479 | 8593 | 17357 | 26839 |
294 | 2.94 | 325 | 749 | 1402 | 3025 | 4595 | 8813 | 17781 | 27533 |
300 | 3 | 328 | 757 | 1414 | 3055 | 4641 | 8900 | 17956 | 27803 |
310 | 3.1 | 335 | 771 | 1438 | 3112 | 4726 | 9063 | 18280 | 28305 |
314 | 3.14 | 336 | 775 | 1446 | 3129 | 4752 | 9074 | 18380 | 28459 |
320 | 3.2 | 340 | 784 | 1462 | 3163 | 4825 | 9204 | 18579 | 28767 |
327 | 3.27 | 344 | 792 | 1479 | 3198 | 4853 | 9299 | 18779 | 29076 |
333 | 3.33 | 348 | 801 | 1495 | 3230 | 4904 | 9408 | 18979 | 29366 |
340 | 3.4 | 351 | 809 | 1511 | 3263 | 4955 | 9516 | 19178 | 29656 |
342 | 3.42 | 353 | 813 | 1520 | 3279 | 4980 | 9571 | 19278 | 29801 |
353 | 3.53 | 358 | 825 | 1541 | 3328 | 5054 | 9707 | 19550 | 30237 |
359 | 3.59 | 362 | 834 | 1556 | 3361 | 5103 | 9798 | 19732 | 30527 |
360 | 3.6 | 363 | 835 | 1558 | 3365 | 5109 | 9809 | 19754 | 30564 |
372 | 3.72 | 369 | 850 | 1585 | 3423 | 5201 | 9979 | 20094 | 31108 |
376 | 3.76 | 371 | 854 | 1592 | 3438 | 5225 | 10024 | 20185 | 31253 |
380 | 3.8 | 373 | 859 | 1601 | 3457 | 5254 | 10081 | 20299 | 31423 |
392 | 3.92 | 379 | 873 | 1628 | 3515 | 5339 | 10251 | 20639 | 31933 |
400 | 4 | 383 | 883 | 1646 | 3554 | 5398 | 10342 | 20866 | 32274 |
408 | 4.08 | 388 | 892 | 1665 | 3592 | 5457 | 10433 | 21092 | 32614 |
412 | 4.12 | 390 | 896 | 1672 | 3608 | 5479 | 10478 | 21174 | 32750 |
420 | 4.2 | 394 | 906 | 1690 | 3646 | 5536 | 10592 | 21378 | 33090 |
425 | 4.25 | 396 | 912 | 1701 | 3670 | 5570 | 10660 | 21500 | 33294 |
Equipment Piping and Condensate Load
Typical maximum condensate load and equipment outlet pipe size:
Maximum Condensate Load (kg/h) | Outlet Pipe Size (mm, (in)) |
---|---|
200 | 15 (1/2) |
500 | 20 (3/4) |
1000 | 25 (1) |
2000 | 32 (1 1/4) |
3000 | 40 (1 1/2) |
5000 | 50 (2) |
> 5000 | 65 - 100 (2 1/2 - 4) |
Related Topics
• Sizing of Steam and Condensate Pipes
Dimensions of steam and condensate pipe lines. Calculate pressure losses, recommended velocities, capacities and more.
• Steam and Condensate
Design of steam & condensate systems with properties, capacities, sizing of pipe lines, system configuration and more.
Related Documents
Condensate Generated in Cold Steam Pipes - SI Units
Huge amounts of condensate are generated when cold steam pipes are heated up must be drained from the pipes.
Condensate Generated in Cold Steam Pipes - Sizing of Steam Traps
When cold steam pipes are heated up they generate huge amounts of condensate that must be drained away from the pipe through steam traps - in Imperial Units.
Condensate Pipe Lines - Friction Resistance Imperial Units
Friction or major resistance in condensate pipe lines.
Condensate Pipes - Flash Steam Generated
Calculate flash steam generation in condensate pipe lines.
Condensate Pumping
High temperatures and danger of impeller cavitation is the major challenge for condensate pumping in steam systems.
Heating Systems - Steam and Condensate Loads
Calculating steam and condensate loads in steam heated systems.
Insulated Steam Pipes - Condensate Generated
Heat loss from steam pipes generates condensate which must be drained from the system - imperial units.
Insulated Steam Pipes - Condensate Generated (kg/h per 100m)
Heat loss from steam pipes generates condensate which must be drained from the system.
Pipes and Equipment - Identification Labels
Tags and label colors used for mechanical, plumbing and piping systems.
Steam - Condensate Pipe Lines - Capacities (kW)
Maximum capacities for condensate pipe lines in kW steam consumption.
Steam - Gravity Return Condensate Pipes - Capacities
Max. capacities (lb/hour) in gravity condensate return lines.
Steam Pipes - Installation of Drip Legs