Engineering ToolBox - Resources, Tools and Basic Information for Engineering and Design of Technical Applications!

This is an AMP page - Open full page! for all features.

Search is the most efficient way to navigate the Engineering ToolBox!

Hyperbolic Functions

Sponsored Links

Hyperbolic Functions

Hyperbolic functions are combinations of the exponentials ex and e-x.

sinh x = (ex - e-x) / 2                  (1)

cosh x = (ex + e-x) / 2                   (2)

tanh x = sinh x / cosh x = (ex - e-x) / (ex + e-x)                          (3)

Values for Hyperbolic Functions

Hyperbolic Functions
xexe-xsinh xcosh xtanh x
0.00 1 1 0 1 0
0.05 1.0513 0.9512 0.050021 1.00125 0.0499584
0.10 1.1052 0.9048 0.10017 1.00500 0.099668
0.15 1.1618 0.8607 0.15056 1.01127 0.14889
0.20 1.2214 0.8187 0.20134 1.02007 0.19738
0.25 1.2840 0.7788 0.25261 1.03141 0.24492
0.30 1.3499 0.7408 0.30452 1.04534 0.29131
0.35 1.4191 0.7047 0.35719 1.06188 0.33638
0.40 1.4918 0.6703 0.41075 1.08107 0.37995
0.45 1.5683 0.6376 0.46534 1.10297 0.42190
0.50 1.6487 0.6065 0.52110 1.12763 0.46212
0.55 1.7333 0.5769 0.57815 1.15510 0.50052
0.60 1.8221 0.5488 0.63665 1.18547 0.53705
0.65 1.9155 0.5220 0.69675 1.21879 0.57167
0.70 2.0138 0.4966 0.75858 1.25517 0.60437
0.75 2.1170 0.4724 0.82232 1.29468 0.63515
0.80 2.2255 0.4493 0.88811 1.33743 0.66404
0.85 2.3396 0.4274 0.95612 1.38353 0.69107
0.90 2.4596 0.4066 1.0265 1.43309 0.71630
0.95 2.5857 0.3867 1.0995 1.48623 0.73978
1.0 2.7183 0.3679 1.1752 1.54308 0.76159
1.1 3.0042 0.3329 1.3356 1.66852 0.80050
1.2 3.3201 0.3012 1.5095 1.81066 0.83365
1.3 3.6693 0.2725 1.6984 1.97091 0.86172
1.4 4.0552 0.2466 1.9043 2.15090 0.88535
1.5 4.4817 0.2231 2.1293 2.35241 0.90515
1.6 4.9530 0.2019 2.3756 2.57746 0.92167
1.7 5.4739 0.1827 2.6456 2.82832 0.93541
1.8 6.0496 0.1653 2.9422 3.10747 0.94681
1.9 6.6859 0.1496 3.2682 3.41773 0.95624
2.0 7.3891 0.1353 3.6269 3.76220 0.96403
2.5 12.182 0.08208 6.0502 6.13229 0.98661
3.0 20.086 0.04979 10.018 10.068 0.99505
3.5 33.115 0.03020 16.543 16.573 0.99818
4.0 54.598 0.01832 27.290 27.308 0.99933
4.5 90.017 0.01111 45.003 45.014 0.99975
5.0 148.41 0.006738 74.203 74.210 0.99991
5.5 244.69 0.004087 122.34 122.35 0.99997
6.0 403.43 0.002479 201.71 201.72 0.99999
6.5 665.14 0.001503 332.57 332.57 1.00000
7.0 1096.6 0.0009119 548.32 548.32 1.00000
7.5 1808.0 0.0005531 904.02 904.02 1.00000
8.0 2981.0 0.0003355 1490.5 1490.5 1.00000
8.5 4914.8 0.0002035 2457.4 2457.4 1.00000
9.0 8103.1 0.00012341 4051.5 4051.5 1.00000
9.5 13360 0.00007485 6679.9 6679.9 1.00000
10 22026 0.000045400 11013 11013 0.999999996

Inverse Hyperbolic Functions

sinh-1(x) = loge(x + (x2 + 1)1/2)                 (4)

cosh-1(x) = loge(x ± (x2 + 1)1/2)       x ≥ 1                     (5)

tanh-1(x) = 1/2 loge((1 + x) / (1 - x))       x2 ‹ 1                        (6)

Sponsored Links

Related Topics

Mathematics

Mathematical rules and laws - numbers, areas, volumes, exponents, trigonometric functions and more.

Related Documents

Algebraic Expressions

Principal algebraic expressions formulas.

Complex Numbers

Complex numbers are used in alternating current theory and mechanical vector analysis.

Elementary Surfaces

Ellipsoid, sphere, hyperboloid, cone and more.

Fractions

Law of fractions

Law of Cosines

One side of a triangle when the opposite angle and two sides are known.

Oblique Triangle

Calculate oblique triangles.

Polynomial Equation of nth Degree

The polynomial nth degree equation.

Pythagorean Theorem

Verifying square corners.

Spherical and Cylindrical Coordinates

3D cylindrical and spherical coordinate systems

Standard Differentials and Integrals

Equations for differentials and integrals.

Taylor Series

Function as an infinite sum of terms.

Trigonometric Functions

Sine, cosine and tangent - the natural trigonometric functions.

Sponsored Links

Search Engineering ToolBox

Search is the most efficient way to navigate the Engineering ToolBox!

SketchUp Extension - Online 3D modeling!

Add standard and customized parametric components - like flange beams, lumbers, piping, stairs and more - to your Sketchup model with the Engineering ToolBox - SketchUp Extension - enabled for use with the amazing, fun and free SketchUp Make and SketchUp Pro . Add the Engineering ToolBox extension to your SketchUp from the Sketchup Extension Warehouse!

Privacy

We don't collect information from our users. Only emails and answers are saved in our archive. Cookies are only used in the browser to improve user experience.

Some of our calculators and applications let you save application data to your local computer. These applications will - due to browser restrictions - send data between your browser and our server. We don't save this data.

Google use cookies for serving our ads and handling visitor statistics on the AMP pages. Please read Google Privacy & Terms for more information about how you can control adserving and the information collected.

AddThis use cookies for handling links to social media. Please read AddThis Privacy for more information.