Engineering ToolBox - Resources, Tools and Basic Information for Engineering and Design of Technical Applications!

This is an AMP page - Open full page! for all features.

Search is the most efficient way to navigate the Engineering ToolBox!

Noise Exposure - NIOSH Permissible Levels and Duration

Sponsored Links

According the National Institute for Occupational Safety - NIOSH - the exposure to noise should be controlled so that the exposure is less than a max combination of exposure level - L - and duration - t.

The maximum time of exposure at a noise level can be calculated as:

t = 480 / 2(L - 85)/3                                   (1)

where

t = maximum exposure duration (minutes)

L = noise exposure level (dB(A))

3 = exchange rate (dB)

85 = Recommended Exposure Limit - REL (dB(A))

Download and print Noise Level - Maximum Exposure Time Chart

Example - Maximum Exposure Time to Noise

The maximum time a person can be exposed for a noise level 100 dB can be calculated as

t = 480 / 2((100 dB) - 85)/3  

  = 15 minutes

.

Maximum Noise Exposure Time Calculator


Combinations of noise exposure levels and maximum duration time:

Maximum Duration Time vs. Noise Level and Exposure Time
Noise Exposure Level
(dBA)
Duration Time
HoursMinutesSeconds
80 25 24
81 20 10
82 16
83 12 42
84 10 5
85 8
86 6 21
87 5 2
88 4
89 3 10
90 2 31
91 2
92 1 35
93 1 16
94 1
95 47 37
96 37 48
97 30
98 23 49
99 18 59
100 15
101 11 54
102 9 27
103 7 30
104 5 57
105 4 43
106 3 45
107 2 59
108 2 22
109 1 53
110 1 29
111 1 11
112 56
113 45
114 35
115 28
116 22
117 18
118 14
119 11
120 9
121 7
122 6
123 4
124 3
125 3
126 2
127 1
128 1
129 1
130 1
-140 < 1
Sponsored Links

Related Topics

Acoustics

Room acoustics and acoustic properties. decibel A, B and C calculations. Noise Rating (NR) curves. Sound transmission through walls. Calculate sound pressure, sound intensity and sound attenuation.

Related Documents

Human Effects when Exposed to Low-Frequency Noise or Vibration

Physiological effects from low-frequency noise or vibrations.

Human Life Expectancy

Age and life expectancy for men and women.

Noise - Acceptable dBA Level

Acceptable noise - dBA - level at typical common locations.

Noise - EPA Protective Levels

The noise level should not exceed certain values to protect public health and welfare.

Noise - Maximum Daily Dose Level

Maximum daily noise dose level when exposed to periods with different levels.

Noise - Recommended Exposure Limits (REL)

The NIOSH noise Recommended Exposure Limit - REL - for occupational noise

Sound - Hearing Threshold vs. Age

Shift in hearing threshold for men and women vs. age.

Sound Intensity, Power and Pressure Levels

Introduction to decibel, sound power, intensity and pressure.

Sponsored Links

Search Engineering ToolBox

Search is the most efficient way to navigate the Engineering ToolBox!

SketchUp Extension - Online 3D modeling!

Add standard and customized parametric components - like flange beams, lumbers, piping, stairs and more - to your Sketchup model with the Engineering ToolBox - SketchUp Extension - enabled for use with the amazing, fun and free SketchUp Make and SketchUp Pro . Add the Engineering ToolBox extension to your SketchUp from the Sketchup Extension Warehouse!

Privacy

We don't collect information from our users. Only emails and answers are saved in our archive. Cookies are only used in the browser to improve user experience.

Some of our calculators and applications let you save application data to your local computer. These applications will - due to browser restrictions - send data between your browser and our server. We don't save this data.

Google use cookies for serving our ads and handling visitor statistics on the AMP pages. Please read Google Privacy & Terms for more information about how you can control adserving and the information collected.

AddThis use cookies for handling links to social media. Please read AddThis Privacy for more information.