Engineering ToolBox - Resources, Tools and Basic Information for Engineering and Design of Technical Applications!

Oil Viscosity Converter

Convert between commonly used oil viscosity units.

Convert between commonly used oil kinematic viscosity units :

Oil Viscosity Converter

Convert from
Multiply with
Convert to
Poise (P) centiPoise (cP) Reyn Stoke (cm2/sec)
centiStoke
Poise (P) 1 100 1.45×10-5 1 / SG 100 / SG
centiPoise (cP) 0.01 1 1.45×10-7 0.01 / SG 1 / SG
Reyn 6.9×104 6.9×106 1 6.9×104/ SG 6.9×106/ SG
Stoke (cm2/sec)
SG 100 SG 1.45×10-5 SG 1 100
centiStoke 0.01 SG SG 1.45×10-7 SG 0.01 1

SG  = specific gravity of the oil

1 Stoke = 100 mm2/second

Example - Convert Viscosity in Stokes to centiStoke

Oil with kinematic viscosity 0.1 Stoke (10 mm2/s) equals to

0.1 Stoke (100 centiStoke/Stoke) = 10 centiStokes

Kinematic viscosity units converting chart

3D Engineering ToolBox - draw and model technical applications! 2D Engineering ToolBox - create and share online diagram drawing templates! Engineering ToolBox Apps - mobile online and offline engineering applications!

Unit Converter


















































9.4.10

.
Cookie Settings