Engineering ToolBox - Resources, Tools and Basic Information for Engineering and Design of Technical Applications!

Metals - Boiling Points and Specific Heat

Boiling points and specific heat of liquid metals.

Metals - Boiling Points and Specific Heat
MetalVapor Pressure (atm)Specific Heat of Liquid
10-310-6
Boiling Point (K)
(cal/goC)(kJ/kgoC)
Aluminum 1782 1333 0.28 1.18
Antimony 1007 741 0.062 0.26
Beryllium 1793 1347 0.78 3.27
Bismuth 1155 851 0.036 0.15
Cadmium 655 486 0.063 0.26
Chromium 1992 1530 0.224 0.94
Cobalt 2167 1652 0.164 0.69
Copper 1862 1391 0.118 0.49
Gold 2023 1510 0.0355 0.15
Iridium 3253 2515 0.043 0.18
Iron 2093 1594 0.197 0.82
Lead 1230 889 0.033 0.14
Magnesium 857 638 0.32 1.34
Manganese 1495 1131 0.20 0.84
Mercury 393 287 0.00
Molybdenum 3344 2558 0.089 0.37
Nickel 2156 1646 0.175 0.73
Niobium (Columbium) 3523 2721 0.083 0.35
Osmium 0.039 0.16
Platinum 2817 2155 0.043 0.18
Plutonium 2200 1596 0.041 0.17
Potassium 606 430
Rhodium 0.092 0.39
Silicon 2340 1749 0.217 0.91
Silver 1582 1179 0.068 0.28
Sodium 701 504 0.00
Tantalum 3959 3052 0.040 0.17
Thorium 3251 2407 0.047 0.20
Tin 1857 1366 0.058 0.24
Titanium 2405 1827 0.188 0.79
Tungsten 4139 3228 0.040 0.17
Uranium 2861 2128 0.048 0.20
Vanadium 2525 1948 0.207 0.87
Zinc 752 559
  • 1 atm = 101325 Pa (N/m2) = 1.013 bar = 14.696 psi (lb/in2) = 760 torr
3D Engineering ToolBox - draw and model technical applications! 2D Engineering ToolBox - create and share online diagram drawing templates! Engineering ToolBox Apps - mobile online and offline engineering applications!

Unit Converter


















































9.19.10

.
Cookie Settings