Engineering ToolBox - Resources, Tools and Basic Information for Engineering and Design of Technical Applications!

Pipe Flanges and Gaskets - Dimensions

Gasket dimensions according ASME B16.5 Pipe Flanges and Flange Fittings.

Gasket dimensions for ASME B16.5 Pipe Flanges and Flange Fittings:

Pipe Flanges and Gaskets - Dimensions
Nominal Pipe SizeGasket Inside Diameter
- ID -
(inch)
Gasket Outside Diameter - OD - (inches)
Class 150Class 300Class 400Class 600Class 900
1/2 0.84 1.875 2.125 2.125 2.125 2.50
3/4 1.06 2.25 2.625 2.625 2.625 2.75
1 1.31 2.625 2.875 2.875 2.875 3.125
1 1/4 1.66 3 3.25 3.25 3.25 3.50
1 1/2 1.91 3.375 3.75 3.75 3.75 3.875
2 2.38 4.125 4.375 4.375 4.375 5.625
2 1/2 2.88 4.875 5.125 5.125 5.125 6.50
3 3.50 5.375 5.875 5.875 5.875 6.625
4 4.50 6.875 7.125 7.00 7.625 8.125
5 5.56 7.75 8.50 8.375 9.50 9.75
6 6.62 8.75 9.875 9.75 10.50 11.375
8 8.62 11 12.125 12.00 12.625 14.125
10 10.75 13.375 14.25 14.125 15.75 17.125
12 12.75 16.125 16.625 16.50 18.00 19.625

The ASME B16.5 - 1996 Pipe Flanges and Flange Fittings standard covers pressure-temperature ratings, materials, dimensions, tolerances, marking, testing, and methods of designating openings for pipe flanges and flanged fittings.

The standard includes flanges with rating class designations 150, 300, 400, 600, 900, 1500, and 2500 in sizes NPS 1/2 through NPS 24, with requirements given in both metric and U.S units. The Standard is limited to flanges and flanged fittings made from cast or forged materials, and blind flanges and certain reducing flanges made from cast, forged, or plate materials. Also included in this Standard are requirements and recommendations regarding flange bolting, flange gaskets, and flange joints.

Insert flanges to your Sketchup model with the Engineering ToolBox Sketchup Extension

Engineering ToolBox Sketchup Extension - flanges

3D Engineering ToolBox - draw and model technical applications! 2D Engineering ToolBox - create and share online diagram drawing templates! Engineering ToolBox Apps - mobile online and offline engineering applications!

Unit Converter


















































6.6.11

.