Engineering ToolBox - Resources, Tools and Basic Information for Engineering and Design of Technical Applications!

Forged Steel Flanges - Stud Charts

Number of studs, diameter and length for ANSI forged steel flanges ranging class 150 to 1500.

Stud numbers, diameters and lengths for ANSI forged steel flanges 150 lb, 300 lb, 400 lb, 600 lb, 900 lb and 1500 lb can be found in the tables below. The charts are for standard facing and standard pressure ratings flange to flange.

Forged Steel Flanges - Class 150

Forged Steel Flanges - Stud Charts - Class 150
NPS
(in)
No. of
Studs
Diameter of Stud
(in)
Length of Stud
(in)
1/2 4 1/2 2-1/2
3/4 4 1/2 2-1/2
1 4 1/2 2-3/4
1-1/4 4 1/2 2-3/4
1-1/2 4 1/2 3
2 4 5/8 3-1/2
2-1/2 4 5/8 3-3/4
3 4 5/8 3-3/4
3-1/2 8 5/8 3-3/4
4 8 5/8 3-3/4
5 8 3/4 4
6 8 3/4 4-1/4
8 8 3/4 4-1/2
10 12 7/8 4-3/4
12 12 7/8 5
14 12 1 5-1/2
16 16 1 5-1/2
18 16 1-1/8 6
20 20 1-1/8 6-1/2
24 20 1-1/4 7
  • 1 inch = 25.4 mm

Forged Steel Flanges - Class 300

Forged Steel Flanges - Stud Charts - Class 300
NPS
(in)
No. of
Studs
Diameter of Stud
(in)
Length of Stud
(in)
1/2 4 1/2 2-3/4
3/4 4 5/8 3-1/4
1 4 5/8 3-1/4
1-1/4 4 5/8 3-1/2
1-1/2 4 3/4 3-3/4
2 8 5/8 3-3/4
2-1/2 8 3/4 4-1/4
3 8 3/4 4-1/2
3-1/2 8 3/4 4-1/2
4 8 3/4 4-3/4
5 8 3/4 5
6 12 3/4 5
8 12 7/8 5-3/4
10 16 1 6-1/2
12 16 1-1/8 7
14 20 1-1/8 7-1/4
16 20 1-1/4 7-3/4
18 24 1-1/4 8
20 24 1-1/4 8-1/4
24 24 1-1/2 9-1/4

Forged Steel Flanges - Class 400

Forged Steel Flanges - Stud Charts - Class 400
NPS
(in)
No. of
Studs
Diameter of Stud
(in)
Length of Stud
(in)
1/2 4 1/2 3-1/4
3/4 4 5/8 3-3/4
1 4 5/8 3-3/4
1-1/4 4 5/8 4
1-1/2 4 3/4 4-1/2
2 8 5/8 4-1/2
2-1/2 8 3/4 5
3 8 3/4 5-1/4
3-1/2 8 7/8 5-3/4
4 8 7/8 5-3/4
5 8 7/8 6
6 12 7/8 6-1/4
8 12 1 7
10 16 1-1/8 7-3/4
12 16 1-1/4 8-1/4
14 20 1-1/4 8-1/2
16 20 1-3/8 9
18 24 1-3/8 9-1/4
20 24 1-1/2 9-3/4
24 24 1-3/4 10-3/4

Forged Steel Flanges - Class 600

Forged Steel Flanges - Stud Charts - Class 600
NPS
(in)
No. of
Studs
Diameter of Stud
(in)
Length of Stud
(in)
1/2 4 1/2 3-1/4
3/4 4 5/8 3-3/4
1 4 5/8 3-3/4
1-1/4 4 5/8 4
1-1/2 4 3/4 4-1/2
2 8 5/8 4-1/2
2-1/2 8 3/4 5
3 8 3/4 5-1/4
3-1/2 8 7/8 5-3/4
4 8 7/8 6
5 8 1 6-3/4
6 12 1 7
8 12 1-1/8 7-3/4
10 16 1-1/4 8-3/4
12 20 1-1/4 9
14 20 1-3/8 9-1/2
16 20 1-1/2 10-1/4
18 20 1-5/8 11
20 24 1-5/8 11-1/2
24 24 1-7/8 13

Forged Steel Flanges - Class 900

Forged Steel Flanges - Stud Charts - Class 900
NPS
(in)
No. of
Studs
Diameter of Stud
(in)
Length of Stud
(in)
1/2 4 3/4 4-1/2
3/4 4 3/4 4-3/4
1 4 7/8 5-1/4
1-1/4 4 7/8 5-1/4
1-1/2 4 1 5-3/4
2 8 7/8 6
2-1/2 8 1 6-1/2
3 8 7/8 6
4 8 1-1/8 7
5 8 1-1/4 7-3/4
6 12 1-1/8 7-3/4
8 12 1-3/8 9
10 16 1-3/8 9-1/2
12 20 1-3/8 10-1/4
14 20 1-1/2 11
16 20 1-5/8 11-1/2
18 20 1-7/8 13
20 20 2 14
24 20 2-1/2 17-1/2

Forged Steel Flanges - Class 1500

Forged Steel Flanges - Stud Charts - Class 1500
NPS
(in)
No. of
Studs
Diameter of Stud
(in)
Length of Stud
(in)
1/2 4 3/4 4-1/2
3/4 4 3/4 4-3/4
1 4 7/8 5-1/4
1-1/4 4 7/8 5-1/4
1-1/2 4 1 5-3/4
2 8 7/8 6
2-1/2 8 1 6-1/2
3 8 1-1/8 7-1/4
4 8 1-1/4 8
5 8 1-1/2 10
6 12 1-3/8 10-1/2
8 12 1-5/8 11-3/4
10 12 1-7/8 13-1/2
12 16 2 15
14 16 2-1/4 16-1/2
16 16 2-1/2 18
18 16 2-3/4 19-1/2
20 16 3 21-1/2
24 16 3-1/2 24-1/2
3D Engineering ToolBox - draw and model technical applications! 2D Engineering ToolBox - create and share online diagram drawing templates! Engineering ToolBox Apps - mobile online and offline engineering applications!

Unit Converter


















































9.19.10

.
Cookie Settings