Steel Pipes Schedule 40 - Velocity Head vs. Water Flow
Velocity head can be used to calculate minor pressure or head loss in fluid flow systems.
Velocity Head in the table below can be used to calculate the minor loss in schedule 40 steel pipes with water flow. Major and minor loss must be summarized for calculating the total head loss in the system.
- 1 ft (foot) = 0.3048 m
| Flow (gal/min) | 1 1/4" | 1 1/2" | 2" | |||
|---|---|---|---|---|---|---|
| Velocity - v - (ft/s) | Velocity Head - v2/2g - (ft) | Velocity - v - (ft/s) | Velocity Head - v2/2g - (ft) | Velocity - v - (ft/s) | Velocity Head - v2/2g - (ft) | |
| 3 | 0.64 | 0.006 | ||||
| 4 | 0.86 | 0.011 | ||||
| 5 | 1.07 | 0.018 | ||||
| 6 | 1.29 | 0.026 | 0.95 | 0.010 | 0.57 | 0.005 |
| 7 | 1.50 | 0.035 | 1.10 | 0.014 | 0.67 | 0.007 |
| 8 | 1.72 | 0.046 | 1.26 | 0.019 | 0.77 | 0.009 |
| 9 | 1.93 | 0.058 | 1.42 | 0.025 | 0.86 | 0.012 |
| 10 | 2.15 | 0.072 | 1.58 | 0.031 | 0.96 | 0.014 |
| 12 | 2.57 | 0.103 | 1.89 | 0.056 | 1.15 | 0.021 |
| 14 | 3.0 | 0.140 | 2.21 | 0.076 | 1.34 | 0.028 |
| 16 | 3.43 | 0.183 | 2.52 | 0.099 | 1.53 | 0.036 |
| 18 | 3.86 | 0.232 | 2.84 | 0.125 | 1.72 | 0.046 |
| 20 | 4.29 | 0.286 | 3.15 | 0.154 | 1.91 | 0.057 |
| 22 | 4.72 | 0.346 | 3.47 | 0.187 | 2.10 | 0.069 |
| 24 | 5.15 | 0.412 | 3.78 | 0.222 | 2.29 | 0.082 |
| 26 | 5.58 | 0.483 | 4.10 | 0.261 | 2.49 | 0.096 |
| 28 | 6.01 | 0.561 | 4.41 | 0.303 | 2.68 | 0.111 |
| 30 | 6.44 | 0.644 | 4.73 | 0.347 | 2.87 | 0.128 |
| 35 | 7.51 | 0.877 | 5.52 | 0.472 | 3.35 | 0.174 |
| 40 | 8.58 | 1.14 | 6.30 | 0.618 | 3.87 | 0.227 |
| 45 | 9.65 | 1.44 | 7.09 | 0.782 | 4.30 | 0.288 |
| 50 | 10.7 | 1.79 | 7.88 | 0.965 | 4.78 | 0.355 |
| 55 | 11.8 | 2.16 | 8.67 | 1.17 | 5.26 | 0.430 |
| 60 | 12.9 | 2.57 | 9.46 | 1.39 | 5.74 | 0.511 |
| 65 | 13.9 | 3.02 | 10.24 | 1.63 | 6.21 | 0.600 |
| 70 | 15.0 | 3.50 | 11.03 | 1.89 | 6.69 | 0.696 |
| 75 | 16.1 | 4.02 | 11.8 | 2.17 | 7.17 | 0.799 |
| 80 | 17.2 | 4.58 | 12.6 | 2.47 | 7.65 | 0.909 |
| 85 | 18.2 | 5.17 | 13.4 | 2.79 | 8.13 | 1.03 |
| 90 | 19.3 | 5.79 | 14.2 | 3.13 | 8.60 | 1.15 |
| 95 | 15.0 | 3.48 | 9.08 | 1.28 | ||
| 100 | 15.8 | 3.86 | 9.56 | 1.42 | ||
| 120 | 11.5 | 2.05 | ||||
| 140 | 13.4 | 2.78 | ||||
| 160 | 15.3 | 3.64 | ||||
| 180 | 17.2 | 4.60 | ||||
| 200 | 19.1 | 5.68 | ||||
- 1 ft (foot) = 0.3048 m
| Flow (gal/min) | 2 1/2" | 3" | 4" | |||
|---|---|---|---|---|---|---|
| Velocity - v - (ft/s) | Velocity Head - v2/2g - (ft) | Velocity - v - (ft/s) | Velocity Head - v2/2g - (ft) | Velocity - v - (ft/s) | Velocity Head - v2/2g - (ft) | |
| 14 | 0.94 | 0.014 | ||||
| 16 | 10.7 | 0.018 | ||||
| 18 | 1.21 | 0.023 | ||||
| 20 | 1.34 | 0.028 | ||||
| 22 | 1.47 | 0.034 | 0.95 | 0.026 | 0.55 | 0.005 |
| 24 | 1.61 | 0.040 | 1.04 | 0.036 | 0.60 | 0.006 |
| 26 | 1.74 | 0.047 | 1.13 | 0.047 | 0.66 | 0.007 |
| 28 | 1.88 | 0.055 | 1.22 | 0.059 | 0.71 | 0.008 |
| 30 | 2.01 | 0.063 | 1.3 | 0.073 | 0.76 | 0.009 |
| 35 | 2.35 | 0.086 | 1.52 | 0.089 | 0.88 | 0.012 |
| 40 | 2.68 | 0.112 | 1.74 | 0.105 | 1.01 | 0.016 |
| 45 | 3.02 | 0.141 | 1.95 | 0.124 | 1.14 | 0.020 |
| 50 | 3.35 | 0.174 | 2.17 | 0.143 | 1.26 | 0.025 |
| 55 | 3.69 | 0.211 | 2.39 | 0.165 | 1.39 | 0.030 |
| 60 | 4.02 | 0.251 | 2.6 | 0.187 | 1.51 | 0.036 |
| 65 | 4.36 | 0.295 | 2.82 | 0.211 | 1.64 | 0.042 |
| 70 | 4.69 | 0.342 | 3.04 | 0.237 | 1.76 | 0.048 |
| 75 | 5.03 | 0.393 | 3.25 | 0.264 | 1.89 | 0.056 |
| 80 | 5.36 | 0.447 | 3.47 | 0.293 | 2.02 | 0.063 |
| 85 | 5.70 | 0.504 | 3.69 | 0.354 | 2.15 | 0.071 |
| 90 | 6.03 | 0.565 | 3.91 | 0.421 | 2.27 | 0.080 |
| 95 | 6.37 | 0.630 | 4.12 | 0.495 | 2.40 | 0.089 |
| 100 | 6.70 | 0.698 | 4.34 | 0.574 | 2.52 | 0.099 |
| 110 | 7.37 | 0.844 | 4.77 | 0.659 | 2.77 | 0.119 |
| 120 | 8.04 | 1.00 | 5.21 | 0.749 | 3.02 | 0.142 |
| 130 | 8.71 | 1.18 | 5.64 | 0.846 | 3.28 | 0.167 |
| 140 | 9.38 | 1.37 | 6.08 | 0.948 | 3.53 | 0.193 |
| 150 | 10.05 | 1.57 | 6.51 | 1.06 | 3.78 | 0.22 |
| 160 | 10.7 | 1.79 | 6.94 | 1.17 | 4.03 | 0.253 |
| 170 | 11.4 | 2.02 | 7.38 | 1.42 | 4.28 | 0.285 |
| 180 | 12.1 | 2.26 | 7.81 | 1.69 | 4.54 | 0.320 |
| 190 | 12.7 | 2.52 | 8.25 | 1.98 | 4.79 | 0.356 |
| 200 | 13.4 | 2.79 | 8.68 | 2.29 | 5.04 | 0.395 |
| 220 | 14.7 | 3.38 | 9.55 | 2.63 | 5.54 | 0.478 |
| 240 | 16.1 | 4.02 | 10.4 | 3.0 | 6.05 | 0.569 |
| 260 | 17.4 | 4.72 | 11.3 | 3.38 | 6.55 | 0.667 |
| 280 | 18.8 | 5.47 | 12.2 | 3.79 | 7.06 | 0.774 |
| 300 | 20.1 | 6.28 | 13.0 | 4.23 | 7.56 | 0.888 |
| 320 | 13.9 | 4.68 | 8.06 | 1.01 | ||
| 340 | 8.57 | 1.14 | ||||
| 360 | 9.07 | 1.28 | ||||
| 380 | 9.58 | 1.43 | ||||
| 400 | 10.1 | 1.58 | ||||
| 420 | 10.6 | 1.74 | ||||
| 440 | 11.1 | 1.91 | ||||
| 460 | 11.6 | 20.9 | ||||
| 480 | 12.1 | 2.27 | ||||
| 500 | 12.6 | 2.47 | ||||
| 550 | 13.9 | 2.99 | ||||
| 600 | 15.1 | 3.55 | ||||
| 650 | 16.4 | 4.17 | ||||
| 700 | 17.6 | 4.84 | ||||
- 1 ft (foot) = 0.3048 m
| Flow (gal/min) | 5" | 6" | 8" | |||
|---|---|---|---|---|---|---|
| Velocity - v - (ft/s) | Velocity Head - v2/2g - (ft) | Velocity - v - (ft/s) | Velocity Head - v2/2g - (ft) | Velocity - v - (ft/s) | Velocity Head - v2/2g - (ft) | |
| 40 | 0.64 | 0.006 | 0.44 | 0.003 | 0.26 | 0.001 |
| 50 | 0.80 | 0.010 | 0.56 | 0.005 | 0.32 | 0.002 |
| 60 | 0.96 | 0.014 | 0.67 | 0.007 | 0.39 | 0.002 |
| 70 | 1.12 | 0.020 | 0.78 | 0.009 | 0.45 | 0.003 |
| 80 | 1.28 | 0.026 | 0.89 | 0.012 | 0.51 | 0.004 |
| 90 | 1.44 | 0.032 | 1.0 | 0.016 | 0.58 | 0.005 |
| 100 | 1.60 | 0.040 | 1.11 | 0.019 | 0.67 | 0.006 |
| 120 | 1.92 | 0.058 | 1.33 | 0.028 | 0.77 | 0.009 |
| 140 | 2.25 | 0.078 | 1.55 | 0.038 | 0.90 | 0.013 |
| 160 | 2.57 | 0.102 | 1.78 | 0.049 | 1.03 | 0.016 |
| 180 | 2.89 | 0.129 | 2.0 | 0.062 | 1.15 | 0.021 |
| 200 | 3.21 | 0.160 | 2.22 | 0.077 | 1.28 | 0.026 |
| 220 | 3.53 | 0.193 | 2.44 | 0.093 | 1.41 | 0.031 |
| 240 | 3.85 | 0.230 | 2.66 | 0.110 | 1.54 | 0.037 |
| 260 | 4.17 | 0.270 | 2.89 | 0.130 | 1.67 | 0.043 |
| 280 | 4.49 | 0.313 | 3.11 | 0.150 | 1.80 | 0.050 |
| 300 | 4.81 | 0.360 | 3.33 | 0.172 | 1.92 | 0.058 |
| 320 | 5.13 | 0.409 | 3.55 | 0.196 | 2.05 | 0.066 |
| 340 | 5.45 | 0.462 | 3.78 | 0.222 | 2.18 | 0.074 |
| 360 | 5.77 | 0.518 | 4.0 | 0.240 | 2.31 | 0.083 |
| 380 | 6.09 | 0.577 | 4.22 | 0.277 | 2.44 | 0.092 |
| 400 | 6.41 | 0.639 | 4.44 | 0.307 | 2.57 | 0.102 |
| 420 | 6.74 | 0.705 | 4.66 | 0.338 | 2.7 | 0.113 |
| 440 | 7.06 | 0.774 | 4.89 | 0.371 | 2.83 | 0.124 |
| 460 | 7.38 | 0.846 | 5.11 | 0.405 | 2.96 | 0.135 |
| 480 | 7.7 | 0.921 | 5.33 | 0.442 | 3.08 | 0.147 |
| 500 | 8.02 | 1.0 | 5.55 | 0.479 | 3.21 | 0.160 |
| 550 | 8.82 | 1.21 | 6.11 | 0.580 | 3.53 | 0.193 |
| 600 | 9.62 | 1.44 | 6.66 | 0.690 | 3.85 | 0.230 |
| 650 | 10.4 | 1.69 | 7.22 | 0.810 | 4.17 | 0.271 |
| 700 | 11.2 | 1.96 | 7.77 | 0.939 | 4.49 | 0.313 |
| 750 | 12.0 | 2.25 | 8.33 | 1.08 | 4.81 | 0.360 |
| 800 | 12.8 | 2.56 | 8.88 | 1.23 | 5.13 | 0.409 |
| 850 | 13.6 | 2.89 | 9.44 | 1.38 | 5.45 | 0.462 |
| 900 | 14.4 | 3.24 | 9.99 | 1.55 | 5.77 | 0.518 |
| 950 | 15.2 | 3.61 | 10.5 | 1.73 | 6.09 | 0.577 |
| 1000 | 16.0 | 4.0 | 11.1 | 1.92 | 6.41 | 0.639 |
| 1100 | 17.6 | 4.84 | 12.2 | 2.32 | 7.05 | 0.773 |
| 1200 | 19.2 | 5.76 | 13.3 | 2.76 | 7.70 | 0.920 |
| 1300 | 20.8 | 6.75 | 14.4 | 3.24 | 8.34 | 1.08 |
| 1400 | 22.5 | 7.83 | 15.5 | 3.76 | 8.98 | 1.25 |
| 1500 | 24.1 | 8.99 | 16.7 | 4.31 | 9.62 | 1.44 |
| 1600 | 25.7 | 10.2 | 17.8 | 4.91 | 10.3 | 1.64 |
| 1700 | 27.3 | 11.6 | 18.9 | 5.54 | 10.9 | 1.85 |
| 1800 | 28.8 | 12.9 | 20.0 | 6.21 | 11.5 | 2.07 |
| 1900 | 30.5 | 14.4 | 21.1 | 6.92 | 12.2 | 2.31 |
| 2000 | 32.1 | 16.0 | 22.2 | 7.67 | 12.8 | 2.56 |
| 2200 | 24.4 | 9.27 | 14.1 | 3.09 | ||
| 2400 | 26.6 | 11.1 | 15.4 | 3.68 | ||
| 2600 | 16.7 | 4.32 | ||||
| 2800 | 18.0 | 5.01 | ||||
| 3000 | 19.2 | 5.75 | ||||