Forged Steel Flanges - Stud Charts

Number of studs, diameter and length for ANSI forged steel flanges ranging class 150 to 1500.

Stud numbers, diameters and lengths for ANSI forged steel flanges 150 lb, 300 lb, 400 lb, 600 lb, 900 lb and 1500 lb can be found in the tables below. The charts are for standard facing and standard pressure ratings flange to flange.

Forged Steel Flanges - Class 150

Forged Steel Flanges - Stud Charts - Class 150
NPS
(in)
No. of
Studs
Diameter of Stud
(in)
Length of Stud
(in)
1/2 4 1/2 2-1/2
3/4 4 1/2 2-1/2
1 4 1/2 2-3/4
1-1/4 4 1/2 2-3/4
1-1/2 4 1/2 3
2 4 5/8 3-1/2
2-1/2 4 5/8 3-3/4
3 4 5/8 3-3/4
3-1/2 8 5/8 3-3/4
4 8 5/8 3-3/4
5 8 3/4 4
6 8 3/4 4-1/4
8 8 3/4 4-1/2
10 12 7/8 4-3/4
12 12 7/8 5
14 12 1 5-1/2
16 16 1 5-1/2
18 16 1-1/8 6
20 20 1-1/8 6-1/2
24 20 1-1/4 7
  • 1 inch = 25.4 mm

Forged Steel Flanges - Class 300

Forged Steel Flanges - Stud Charts - Class 300
NPS
(in)
No. of
Studs
Diameter of Stud
(in)
Length of Stud
(in)
1/2 4 1/2 2-3/4
3/4 4 5/8 3-1/4
1 4 5/8 3-1/4
1-1/4 4 5/8 3-1/2
1-1/2 4 3/4 3-3/4
2 8 5/8 3-3/4
2-1/2 8 3/4 4-1/4
3 8 3/4 4-1/2
3-1/2 8 3/4 4-1/2
4 8 3/4 4-3/4
5 8 3/4 5
6 12 3/4 5
8 12 7/8 5-3/4
10 16 1 6-1/2
12 16 1-1/8 7
14 20 1-1/8 7-1/4
16 20 1-1/4 7-3/4
18 24 1-1/4 8
20 24 1-1/4 8-1/4
24 24 1-1/2 9-1/4

Forged Steel Flanges - Class 400

Forged Steel Flanges - Stud Charts - Class 400
NPS
(in)
No. of
Studs
Diameter of Stud
(in)
Length of Stud
(in)
1/2 4 1/2 3-1/4
3/4 4 5/8 3-3/4
1 4 5/8 3-3/4
1-1/4 4 5/8 4
1-1/2 4 3/4 4-1/2
2 8 5/8 4-1/2
2-1/2 8 3/4 5
3 8 3/4 5-1/4
3-1/2 8 7/8 5-3/4
4 8 7/8 5-3/4
5 8 7/8 6
6 12 7/8 6-1/4
8 12 1 7
10 16 1-1/8 7-3/4
12 16 1-1/4 8-1/4
14 20 1-1/4 8-1/2
16 20 1-3/8 9
18 24 1-3/8 9-1/4
20 24 1-1/2 9-3/4
24 24 1-3/4 10-3/4

Forged Steel Flanges - Class 600

Forged Steel Flanges - Stud Charts - Class 600
NPS
(in)
No. of
Studs
Diameter of Stud
(in)
Length of Stud
(in)
1/2 4 1/2 3-1/4
3/4 4 5/8 3-3/4
1 4 5/8 3-3/4
1-1/4 4 5/8 4
1-1/2 4 3/4 4-1/2
2 8 5/8 4-1/2
2-1/2 8 3/4 5
3 8 3/4 5-1/4
3-1/2 8 7/8 5-3/4
4 8 7/8 6
5 8 1 6-3/4
6 12 1 7
8 12 1-1/8 7-3/4
10 16 1-1/4 8-3/4
12 20 1-1/4 9
14 20 1-3/8 9-1/2
16 20 1-1/2 10-1/4
18 20 1-5/8 11
20 24 1-5/8 11-1/2
24 24 1-7/8 13

Forged Steel Flanges - Class 900

Forged Steel Flanges - Stud Charts - Class 900
NPS
(in)
No. of
Studs
Diameter of Stud
(in)
Length of Stud
(in)
1/2 4 3/4 4-1/2
3/4 4 3/4 4-3/4
1 4 7/8 5-1/4
1-1/4 4 7/8 5-1/4
1-1/2 4 1 5-3/4
2 8 7/8 6
2-1/2 8 1 6-1/2
3 8 7/8 6
4 8 1-1/8 7
5 8 1-1/4 7-3/4
6 12 1-1/8 7-3/4
8 12 1-3/8 9
10 16 1-3/8 9-1/2
12 20 1-3/8 10-1/4
14 20 1-1/2 11
16 20 1-5/8 11-1/2
18 20 1-7/8 13
20 20 2 14
24 20 2-1/2 17-1/2

Forged Steel Flanges - Class 1500

Forged Steel Flanges - Stud Charts - Class 1500
NPS
(in)
No. of
Studs
Diameter of Stud
(in)
Length of Stud
(in)
1/2 4 3/4 4-1/2
3/4 4 3/4 4-3/4
1 4 7/8 5-1/4
1-1/4 4 7/8 5-1/4
1-1/2 4 1 5-3/4
2 8 7/8 6
2-1/2 8 1 6-1/2
3 8 1-1/8 7-1/4
4 8 1-1/4 8
5 8 1-1/2 10
6 12 1-3/8 10-1/2
8 12 1-5/8 11-3/4
10 12 1-7/8 13-1/2
12 16 2 15
14 16 2-1/4 16-1/2
16 16 2-1/2 18
18 16 2-3/4 19-1/2
20 16 3 21-1/2
24 16 3-1/2 24-1/2

Related Topics

Related Documents

Search

Search is the most efficient way to navigate the Engineering ToolBox.

Engineering ToolBox - SketchUp Extension - Online 3D modeling!

3D Engineering ToolBox Extension to SketchUp - add parametric components to your SketchUp model

Add standard and customized parametric components - like flange beams, lumbers, piping, stairs and more - to your Sketchup model with the Engineering ToolBox - SketchUp Extension - enabled for use with older versions of the amazing SketchUp Make and the newer "up to date" SketchUp Pro . Add the Engineering ToolBox extension to your SketchUp Make/Pro from the Extension Warehouse !

Translate this Page

Translate this page to Your Own Language .

About the Engineering ToolBox!

Privacy Policy

We don't collect information from our users. More about

We use a third-party to provide monetization technologies for our site. You can review their privacy and cookie policy here.

You can change your privacy settings by clicking the following button: .

Citation

This page can be cited as

  • The Engineering ToolBox (2005). Forged Steel Flanges - Stud Charts. [online] Available at: https://www.engineeringtoolbox.com/forged-flanges-studs-d_1015.html [Accessed Day Month Year].

Modify the access date according your visit.

3D Engineering ToolBox - draw and model technical applications! 2D Engineering ToolBox - create and share online diagram drawing templates! Engineering ToolBox Apps - mobile online and offline engineering applications!

Unit Converter

















































5.8.12

.