Ethane Liquid - Thermal Properties
Thermal properties of liquid Ethane C2H6 at the vapor liquid phase boundary.
For full table with Density and Speed of Sound - rotate the screen!
Temperature - T - (K) | Pressure - p - (kPa) | Enthalpy - h - (kJ/kg) | Entropy - s - (kJ/(kg K)) | Specific Heat Capacity - cv - (kJ/(kg K)) | Specific Heat - cp - (kJ/(kg K)) | Speed of Sound - c - (m/s) | Density - ρ - (kg/m3) |
---|---|---|---|---|---|---|---|
90.368 (triple point) |
0.0011 | -889 | -5.06 | 1.61 | 2.33 | 2008 | 652 |
120 | 0.352 | -821 | -4.41 | 1.48 | 2.28 | 1794 | 619 |
150 | 9.64 | -752 | -3.90 | 1.44 | 2.33 | 1576 | 585 |
160 | 21.4 | -729 | -3.75 | 1.44 | 2.36 | 1501 | 574 |
170 | 42.8 | -705 | -3.60 | 1.43 | 2.39 | 1426 | 562 |
180 | 78.6 | -681 | -3.46 | 1.43 | 2.42 | 1350 | 550 |
184 | 98.3 | -671 | -3.41 | 1.44 | 2.44 | 1320 | 545 |
Standard Temperature and Pressure | |||||||
186 | 109.4 | -666 | -3.38 | 1.44 | 2.45 | 1305 | 542 |
190 | 134.6 | -656 | -3.33 | 1.44 | 2.46 | 1274 | 537 |
200 | 217.2 | -631 | -3.21 | 1.44 | 2.51 | 1196 | 524 |
210 | 333.8 | -606 | -3.08 | 1.45 | 2.57 | 1117 | 510 |
220 | 492.1 | -580 | -2.96 | 1.47 | 2.65 | 1037 | 496 |
230 | 700.2 | -553 | -2.84 | 1.49 | 2.73 | 956 | 481 |
240 | 966.8 | -525 | -2.73 | 1.51 | 2.85 | 873 | 465 |
250 | 1301 | -496 | -2.61 | 1.53 | 2.99 | 788 | 448 |
260 | 1711 | -465 | -2.49 | 1.57 | 3.20 | 701 | 429 |
270 | 2210 | -432 | -2.38 | 1.61 | 3.49 | 609 | 408 |
280 | 2807 | -397 | -2.25 | 1.65 | 3.99 | 512 | 383 |
300 | 4357 | -305 | -1.95 | 1.91 | 10.02 | 275 | 304 |
305.322 (critical point) |
4872 | -230.7 | -1.71 | 206 |
Ethane is an organic chemical compound with chemical formula C2H6.
Related Topics
• Material Properties
Properties of gases, fluids and solids. Densities, specific heats, viscosities and more.
Related Documents
Combustion Heat
Heat of combustion (energy content) for som common substances - with examples how to calculate heat of combustion.
Ethane - Density and Specific Weight vs. Temperature and Pressure
Online calculator, figures and tables showing density and specific weight of ethane, C2H6, at varying temperature and pressure - Imperial and SI Units.
Ethane - Thermophysical Properties
Chemical, Physical and Thermal Properties of Ethane - C2H6.
Ethane Gas - Specific Heat vs. Temperature
Specific heat of Ethane Gas - C2H6 - for temperatures ranging 250 - 900 K.
Fuel Gases - Heating Values
Combustion heat values for gases like acetylene, blast furnace gas, ethane, biogas and more - Gross and Net values.
Gases - Explosion and Flammability Concentration Limits
Flame and explosion limits for gases like propane, methane, butane, acetylene and more.
Substances Triple Points
Triple points for common substances.